Loading...
HomeMy WebLinkAboutAgenda Item 1 - Kona Hyundai (PL-KVD-2024-000055)Issue Date: Drawn By: Revisions: NOT FOR CONSTRUCTION OR PERMITTING PURPOSES PRELIMINARY Dealer Code 1.This design concept drawing is not intended for construction or permit purposes but to express the general requirements for the project. 2.No representation is being made as to compliance with local State or Federal regulations and neither the designer nor the dealer assumes any responsibility or liability with reference thereto. J Alcivar 08.07.2024 2 of 7 sheets A-1 HI010 Kailua-Kona, HI 96740 75-5793 Kuakini Hwy Big Island Hyundai Existing Floor Diagram Issue Date: Drawn By: Revisions: NOT FOR CONSTRUCTION OR PERMITTING PURPOSES PRELIMINARY Dealer Code 1.This design concept drawing is not intended for construction or permit purposes but to express the general requirements for the project. 2.No representation is being made as to compliance with local State or Federal regulations and neither the designer nor the dealer assumes any responsibility or liability with reference thereto. J Alcivar 08.07.2024 3 of 7 sheets A-2 HI010 Kailua-Kona, HI 96740 75-5793 Kuakini Hwy Big Island Hyundai Existing Exterior Views Issue Date: Drawn By: Revisions: NOT FOR CONSTRUCTION OR PERMITTING PURPOSES PRELIMINARY Dealer Code 1.This design concept drawing is not intended for construction or permit purposes but to express the general requirements for the project. 2.No representation is being made as to compliance with local State or Federal regulations and neither the designer nor the dealer assumes any responsibility or liability with reference thereto. J Alcivar 08.07.2024 4 of 7 sheets A-3 HI010 Kailua-Kona, HI 96740 75-5793 Kuakini Hwy Big Island Hyundai Proposed Site Diagram “” KUAKINI HWY PLANNING GUIDE : 265 PG REQUIREMENT TOTAL PROVIDED TOTAL SITE AREA (sq ft)49200 26953 SALES USABLE LAND AREA (sq ft)32300 14995 SERVICE USABLE LAND AREA (sq ft)7200 7200 TOTAL USABLE LAND AREA (sq ft)39500 22195 PG REQUIREMENT PROVIDED - 1st FLOOR PROVIDED - 2nd FLOOR TOTAL PROVIDED SHOWROOM & OFFICE AREA (sq ft)n/a 0 SHOWROOM DISPLAY VEHICLES #3 1 1 CUSTOMER FACING AREA (sq ft)2930 1490 1490 GENERAL ADMIN / BUSINESS OFFICE (sq ft)770 985 985 TOTAL CUSTOMER FACING + ADMIN (sq ft)3700 1490 985 2475 SERVICE DRIVE (sq ft)1800 1006 1006 SERVICE DRIVE VEHICLES #4 2 2 SERVICE WORKSHOP (sq ft)3150 1800 1800 SERVICE BAYS & LIFTS #6 4 4 PARTS DEPT/STORAGE (sq ft)1050 462 478 940 TOTAL SERVICE & PARTS AREA (sq ft)6000 3268 3268 TOTAL BUILDING AREA (sq ft)9700 4758 985 5743 Issue Date: Drawn By: Revisions: NOT FOR CONSTRUCTION OR PERMITTING PURPOSES PRELIMINARY Dealer Code 1.This design concept drawing is not intended for construction or permit purposes but to express the general requirements for the project. 2.No representation is being made as to compliance with local State or Federal regulations and neither the designer nor the dealer assumes any responsibility or liability with reference thereto. J Alcivar 08.07.2024 5 of 7 sheets A-4 HI010 Kailua-Kona, HI 96740 75-5793 Kuakini Hwy Big Island Hyundai Proposed Floor Diagram RE: Arch. Dwgs OUTER ACM LAYER: 4MM HYUNDAI NORTH AMERICAN BRONZE ACM, SHAPED SKY PANEL OVERLAY (BY HMA APPROVED ACM VENDOR) BASE ACM LAYER: 4MM BLACK ACM RAINSCREEN (BY HMA APPROVED ACM VENDOR) INSTALLED OVER WEATHER-PROOFING OVER 34" TREATED PLYWOOD SHEATHING (BY GC) Slope to Rear ROOFING RE: ARCH. DWGS. STRUCTURE RE: ENGR. DWGS. OUTER ACM LAYER: 4MM HYUNDAI NORTH AMERICAN BRONZE ACM, SHAPED SKY PANEL OVERLAY (BY HMA APPROVED ACM VENDOR) BASE ACM LAYER: 4MM BLACK ACM RAINSCREEN (BY HMA APPROVED ACM VENDOR) INSTALLED OVER WEATHER-PROOFING OVER 34" TREATED PLYWOOD SHEATHING (BY GC) STRUCTURE RE: ENGR. DWGS. SHAPED SKY SOFFIT STRUCTURE RE: ENGR. DWGS. SHAPED SKY CEILING: 4MM HYUNDAI NORTH AMERICAN BRONZE ACM, SHAPED SKY PANEL OVERLAY (BY HMA APPROVED ACM VENDOR) OVER BLACK ARMSTRONG PRELUDE XL 1516" 2'x2' CEILING GRID, WITH HD HANGER WIRES, OR EQUAL (BY GC) WITH 2'x2' BLACK METAL INSERT PANELS (BY HMA APPROVED ACM VENDOR) SHAPED SKY SOFFIT & FASCIA: 4MM HYUNDAI NORTH AMERICAN BRONZE ACM, SHAPED SKY PANEL OVERLAY OVER 4MM BLACK ACM RAINSCREEN (BY HMA APPROVED ACM VENDOR) INSTALLED OVER WEATHER-PROOFING OVER 34" TREATED PLYWOOD SHEATHING (BY GC) ALIGN Scale: Cap Diagram13/4"=1'-0" Scale: Soffit Diagram23/4"=1'-0" Scale: ACM Transition Diagram33/4"=1'-0" Issue Date: Drawn By: Revisions: NOT FOR CONSTRUCTION OR PERMITTING PURPOSES PRELIMINARY Dealer Code 1.This design concept drawing is not intended for construction or permit purposes but to express the general requirements for the project. 2.No representation is being made as to compliance with local State or Federal regulations and neither the designer nor the dealer assumes any responsibility or liability with reference thereto. J Alcivar 08.07.2024 6 of 7 sheets A-5 HI010 Kailua-Kona, HI 96740 75-5793 Kuakini Hwy Big Island Hyundai Proposed Reflected Ceiling Diagram ACM SOFFIT 11'-11" AFF ACM CLG 11'-11" AFF ACT CLG 12-6" AFF GYP CLG 8'-0" AFF ACM CLG 11'-6" AFF ACT CLG 9'-0" AFF ACM CLG 11'-11" AFF EIFS CLG 11-11" AFF Big Island Service Issue Date: Drawn By: Revisions: NOT FOR CONSTRUCTION OR PERMITTING PURPOSES PRELIMINARY Dealer Code 1.This design concept drawing is not intended for construction or permit purposes but to express the general requirements for the project. 2.No representation is being made as to compliance with local State or Federal regulations and neither the designer nor the dealer assumes any responsibility or liability with reference thereto. J Alcivar 08.07.2024 7 of 7 sheets A-6 HI010 Kailua-Kona, HI 96740 75-5793 Kuakini Hwy Big Island Hyundai Proposed Exterior Views HI015 Big Island Hyundai M. GrossCAM: AGI Rep: Drawn By: NSA / P Petkov J Alcivar N/A 09/19/2024 Wall Signs Art represents an approximation of sign and aluminum composite material (ACM) panel appearance. Dealer to provide 120-volt, 20-amp dedicated circuit to each sign. Larger sets may require additional circuits. Dealer to provide behind-the-wall access for installation and structural support for signs. Dealer is responsible for covering signage mounting/wires/transformers if they are visible on the inside of the building. If an engineer alters quoted signage a change order will be provided to the dealer. Please refer to AGI’s Architectural Imaging’s ACM proposal for details on that separate scope of work. Copy on and placement of signs to be verified by dealer. Proposal assumes the completed building will require a field survey to determine if any signage modifications are necessary. A change order will be provided if necessary. Dealer to supply notes above to GC, architect, and other construction team members. Rendering based on AGI conceptual design drawings from Jose Alcivar 9/4/24. Dealer is responsible for verifying that this brandbook matches final architectural plans. Scale: Date: FRONT ELEVATION If dealer desires signage as shown he will need to seek variance with local jurisdiction. Site is allowed 22 sq. ft. HI015 Big Island Hyundai 75-5793 Kuakini Hwy Kailua Kona, HI 96740 HEG-111.60 sq. ft.DNW-18F11.42 sq. ft. 23.87 sq. ft. HCS-22F HCL-16F 3'-6 3/8"2'-8"2'-8"7 7/16"8'-11 1/4" 13'-1 1/16"7 3/16"2 7/8"11 5/8"CL CLBig Island CAM: AGI Rep: Drawn By: M. Gross J Alcivar 09/19/2024 HI015 Big Island Hyundai 75-5793 Kuakini Hwy Kailua Kona, HI 96740 NSA / P Petkov N/AScale: Date: FRONT SERVICE ELEVATION SW-18F9.9 sq. ft. CL CL Wall Signs Art represents an approximation of sign and aluminum composite material (ACM) panel appearance. Dealer to provide 120-volt, 20-amp dedicated circuit to each sign. Larger sets may require additional circuits. Dealer to provide behind-the-wall access for installation and structural support for signs. Dealer is responsible for covering signage mounting/wires/transformers if they are visible on the inside of the building. If an engineer alters quoted signage a change order will be provided to the dealer. Please refer to AGI’s Architectural Imaging’s ACM proposal for details on that separate scope of work. Copy on and placement of signs to be verified by dealer. Proposal assumes the completed building will require a field survey to determine if any signage modifications are necessary. A change order will be provided if necessary. Dealer to supply notes above to GC, architect, and other construction team members. Rendering based on AGI conceptual design drawings from Jose Alcivar 9/4/24. Dealer is responsible for verifying that this brandbook matches final architectural plans. Need lane signal indicators shown to determine position of Service letters. Currently, Service letters are shown centered on the bronze ACM fascia. M. Gross J Alcivar 09/19/2024 HI015 Big Island Hyundai 75-5793 Kuakini Hwy Kailua Kona, HI 96740 NSA / P Petkov NTSAGI Rep: Drawn By: Scale: Date: CAM: HEG-111.60 sq. ft. (Symbol & Logo)7 3/16"2 7/8"11 5/8"1' - 7 13/16" SW-18F 9.9 sq. ft. 6' - 7 5/16"1' - 6"7' - 7 13/32"1' - 6"Big Island DNW-18F 11.42 sq. ft. 23.87 sq. ft.HCS-22F HCL-16F 3' - 6 3/8"7 7/16"8' - 11 1/4" 13' - 1 1/16"1' - 3 13/16"1' - 9 7/8"If dealer desires signage as shown he will need to seek variance with local jurisdiction. Site is allowed 22 sq. ft. M. Gross J Alcivar 09/19/2024 HI015 Big Island Hyundai 75-5793 Kuakini Hwy Kailua Kona, HI 96740 NSA / P Petkov NTSAGI Rep: Drawn By: Scale: Date: CAM: Ground Signs Art represents approximation of sign appearance. Ground sign to be installed on new foundation. Exact location of sign to be determined. Final location of sign subject to municipality approval. Ground sign recommendation/pricing assumes installation in earth, without obstructions, on level grade. Dealer to locate private utilities and identify location. Attempt to install ground sign on existing foundation, this requires a survey to confirm adaptability, approval by an engineer(s), and municipality. Dealer to provide 120-volt, 20-amp dedicated circuit to signage. Hyundai directional is NON-Illuminated. If an engineer alters quoted signage a change order will be provided to the dealer. Copy on and placement of any signs, including directional signs, to be verified by dealer. Dealer to supply above to GC, architect, and other construction team members. Wind – ASCE/SEI 7-22 120 Vmph, Special Wind Region (use VHWL), Miles - 5000, Zone - 5, Hawaii GDSI-4-P-8-VHWL Big Island 27.9 sq. ft. May require varianceExact location of sign to be determined. Recommending GDSI-4-P-8-VHWL,which requires variance (over 22 sq. ft. allowance) by dealer. If variance is denied, the GDSI-4-M-4-VHWL is within code. M. Gross J Alcivar 09/19/2024 HI015 Big Island Hyundai 75-5793 Kuakini Hwy Kailua Kona, HI 96740 NSA / P Petkov NTSAGI Rep: Drawn By: Scale: Date: CAM: Rendering based on AGI conceptual design drawings from Jose Alcivar 9/4/24. Dealer is responsible for verifying that this brandbook matches final architectural plans. Ground sign to be installed on new foundation. Exact location of sign to be determined. Final location of sign subject to municipality approval. Ground sign recommendation/pricing assumes installation without obstructions, on level grade. Attempt to install ground sign on existing foundation, this requires a survey to confirm adaptability, approval by an engineer(s), and municipality. Dealer to provide 120-volt, 20 amp dedicated circuit to signage. Hyundai directional is NON-Illuminated. If an engineer alters quoted signage a change order will be provided to the dealer. Copy on and placement of any directional signs to be verified by dealer. Dealer to supply above to GC, architect, and other construction team members. Service Hyundai Entry Element Dealer Name Pylon Entry Element KUAKINI HWY KUAKINI HWY Directional was not included in the DID Issue Set. M. Gross J Alcivar 09/19/2024 HI015 Big Island Hyundai 75-5793 Kuakini Hwy Kailua Kona, HI 96740 NSA / P Petkov • Remove Hyundai logo and letters on showroom – HBL-9 logo, HBC-6 Hyundai letters. • Remove Existing Hyundai pylon, and the stone base (to allow for installation of new sign). NTSAGI Rep: Drawn By: Scale: Date: CAM: Removals and disposal by Dealer: