Loading...
HomeMy WebLinkAboutPV Bulletin 2012-05 BUILDING DIVISION – DPW COUNTY OF HAWAI‘I – 101 Pauahi Street, Suite 7 – Hilo, Hawai‘i 96720 Hilo Office (808) 961-8331  Fax (808) 961-8410 Kona Office (808) 323-4720  Fax (808) 323-3509 Bulletin No : PV 2012-05 Date: March 12, 2013 Code/ Edition : Hawai‘i County Code Chapter 9 and the 2008 National Electrical Code (NEC) Subject : Photovoltaic (PV) energy systems From : Neil Erickson, Plans Examining Manager, nerickson@co.hawaii.hi.us The following clarifications related to PV energy systems are provided: A. PV – ROOF MOUNTED 1. PLAN REVIEW AND APPROVALS Per Hawaii Engineering Group, Inc. President Ather R. Dar, PE, and the certification, specifications and details provided on September 5, 2012: The Zilla Dual Grip Rail System and the Zilla Phantom system are approved for use and may be installed on residential homes with gable roofs in Wind Zones A, B, C, and D and Seismic Zones A, B, C, D, and E and do not require a licensed Hawai‘i state architect or structural engineer’s review and approval (a professional stamp) when designed and installed per the 1 manufacturer’s recommended installation span tables and guidelines. 2. Per Murrar Engineering & Design, Inc. President Kevin Murrar, PE, SE and the certification, specifications and details provided on October 9, 2012: the SunEarth SolarStrut mounting system is approved for use and may be 2 installed on residential homes in Wind Zones A, B,C, and D and Seismic Zones A, B, C, D, and E and do not require a licensed Hawai‘i state architect or structural engineer review and approval (a professional stamp) when designed and installed per the manufacturer’s recommended installation span 3 tables and guidelines. A licensed Hawai‘i state architect or structural engineer must review and approve applications on dwellings greater than a single story. 1 Attachment 1 – October 8, 2012, Standard Zilla Racking Roof Mounting Certification documents from Hawai‘i Engineering Group, Inc. 2 Revised, “with gable roofs” deleted 3 Attachment 1 – October 9, 2012, SunEarth SolarStrut Racking system Certification documents from Murrar Engineering and Design, Inc. The County of Hawai‘i is an Equal Opportunity Employer and Provider 3. Per Delta Engineering, Bahman Kheradpey, SE and the certification, ProStrut specifications and details provided on October 9, 2012: The Aluminum Channel Rail mounting system is approved for use and may be installed on residential homes with gable roofs in Wind Zones A, B, and C and Seismic Zones A, B, C, and D and do not require a licensed Hawai‘i state architect or structural engineer review and approval (a professional stamp) when designed and installed per the manufacturer’s recommended 4 installation span tables and guidelines. A licensed Hawai‘i state architect or structural engineer must review and approve applications on dwellings greater than a single story, in Seismic Zone E within ¼ mile of the ocean (Wind Exposure D). 4. Per Alghan Associates, Inc, Mr. Di Huynh, SE and the certification, HatiCon Solar specifications and details provided on October 12, 2012: The Rail ST-AK 13/60 mounting system is approved for use and may be installed on residential homes with gable roofs in Wind Zones A, B, C, and C and Seismic Zones A, B, and D and do not require a licensed Hawai‘i State architect or structural engineer review and approval (a professional stamp) when designed and installed per the manufacturer’s recommended 5 installation span tables and guidelines. A licensed Hawai‘i state architect or structural engineer must review and approve applications on dwellings greater than 2 stories and 30’ in height, or in Seismic Zone E. 5. Per Norman Scheel Structural Engineer, Norman J. Scheel, PE, SE, and the SnapNrack certification, specifications and details dated June 1, 2012: The PV Mounting System is approved for use and may be installed on residential homes with gable roofs in Wind Zones B, and C, and Seismic Zones A, B, C, D and do not require a licensed Hawai‘i state architect or structural engineer’s review and approval (a professional stamp) when designed and installed per the manufacturer’s recommended installation span 6 tables and guidelines. A licensed Hawaii state architect or structural engineer must review and approve applications within ¼ mile of the ocean (Wind Exposure D), or Seismic Zone “E”. 4 Attachment 1 – October 15, 2012, ProStrut Aluminum Chanel Rail Certification documents from Delta Engineering. 5 Attachment 1 – October 12, 2012, HatiCon Solar ST-AK 13/60 Rail Certification documents from Delta Engineering. 6 Attachment 1 – March 12, 2013, SnapnRack Mounting System, certification, specifications and details from Norman Scheel Structural Engineer, Norman J. Scheel, PE, SE, Issued by: David Yamamoto, Building Division Chief