Loading...
HomeMy WebLinkAbout2-1-001:10101/15/99 15:20 FAX 808 935 2070 WESLEY R SEGAWA ASSOC -, WRSA-HNL a FEDERAL EMERGENCY MANAGEMENT AGENCY NATIONAL FLOOD INSURANCE PROGRAM FLOODPROOFING CERTIFICATE FOR NON-RESIDENTIAL STRUCTURES iD 002 O.M.B. NO. 3067-0077 E*ires May 31,1996 The f/oodproofing of non-residential buildings maybe permitted as an alternative to elevating to or above the Base Flood Elevation; however, a floodproofing design certificationis required. This form is to be used for that certification. Rloodproofing of a residential building does -not alter a community's floodplain management elevation requirements or effect the insurance rating unless the community has been issued orf exception by FEMA to allow floodproofed residential basemerits. The permitting of a floodproofed residential basement requires a separate certification specifying that the design complies- with the local floodp/airs management ordinance. --- - - -- -- - -- BUILDING OWNER'S NAME POLICY NUMBER County of Hawaii STREET ADDRESS. (Including Apt., Unit, Suite and/or Bldg. Number) OR P.O. ROUTE AND.BOX NUMBER COMPANY NAIC NUMBER 25 Auvuni•:-S V. OTHER DESCRIPTION (Lot and Block Numbers, etc.) C11Y STATE ZIP CODE Hilo TM Y-- 2 "j -bo C "Y fol Hawaii 96720 SECTION I FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Provide the following from the proper FIRM: COMMUNITY NUMBER PANEL NUMBER SUFFIX DATE OF FIRM INDEX FIRM ZONE BASE FLOOD ELEVATION tin AO Zones, use depth) 155166 0880 C Sept, 16 1988 VE 9 Ft. SECTION II FLOODPROOFING INFORMATION (Sy a Registered Professional Engineer or Architect) Floodproofing Design Elevation information: Building is floodproofed to an elevation of I I ( l 191 -j -a feet NGVD. (Elevation datum used must be the same as that on the FIRM.) Height of floodproofing on the building above the lowest adjacent grade is 131. VJ feet. (NOTE: for insurance rating purposes, the building's floodproofed design elevation must be at least one foot above the Base Flood Elevation to receive rating credit. If the building Is floodproofed only to the Base Flood Elevation, then the buildings insurance rating will result in a higher premium.) SECTION III CERTIFICATION (By a Registered Professional Engineer or Architect) Non -Residential F000dprooted Construction Certification: I certify that based upon development and/or review of structural design, specifications, and plans for construction that the design and methods of construction are in accordance with accepted standards of practice for meeting the following provisions: The structure, together with attendant utilities and sanitary facilities, is watertight to the floodproofed design elevation indicated above, with walls that are substantially impermeable to the passage of water. • All structural components are capable of resisting hydrostatic and hydrodynamic flood forces, including the effects of buoyancy, and anticip�te�debris impact forces. Asamended per attactment A ; I certify that the information on this certificate represents my best efforts, to interpret the data available. 1 understand that any false statement may be punishable by fine or imprisonment under 78 U.S. Code, Secdon 1001. CERTiFIER'S NAME LICENSE NUMBER (or Affix Seal) Wesley R. Segawa 5116-S Ti FLE - COMPANY NAME President Wesley R. Segawa & Associates, Inc. ADDRESS 101 Silva Street Copies should be CiTY Hilo DATE December 18, 2000 STATE ZIP Hawaii 96720 PHONE (808) 935-4677 e for: 1) community official, 2) insurance agenticompany, and 3) building owner. :EMA Form 81-65, MAY 93 REPLACES EDITION OF MAY. 90, WMCH IS OBSOLETE_ 593.9Od96 (5/93)