My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 044 Draft 02 2020-2022
ClerkCouncil
>
Council Records
>
Bills
>
2020-2022
>
BIL 044 Draft 02 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2021 3:25:33 PM
Creation date
8/10/2021 8:40:07 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2020-2022
Bill/Resolution
044
Draft
02
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
COUNCIL
Action 1
Council: Bill 44 Draft 2, passes first reading - 8/4/21
Action 2
Council: Bill 44 Draft 2, passes second & final reading - 8/18/21
Date To Mayor or Adoption Date
8/27/2021
Reading Number
1
Reading Date
8/4/2021
Ayes
7-Chung, David, Inaba, Kierkiewicz, Kimball, Lee Loy, Richards
Noes
1-Villegas
Absent
1-Kaneali'i-Kleinfelder
Excused
0
Reading Number .
2
Reading Date .
8/18/2021
Ayes .
5-David, Inaba, Kierkiewicz, Kimball, Lee Loy
Noes .
2-Kaneali'i-Kleinfelder, Villegas
Absent .
2-Chung, Richards
Excused .
0
Document Relationships
AGE COUNCIL 2021-08-18 2020-2022
(Related To)
Path:
\Council Records\Agendas\2020-2022\Council
COM 0281.032 2020-2022
(Related)
Path:
\Council Records\Communications\2020-2022
ORD 2021-061 2020-2022
(Related To)
Path:
\Council Records\Ordinances\2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(40) Section R403, "Footings," of the International Residential Code is amended by <br /> adding subsection R403.1.6.3, "Anchor bolts at the perimeter edge of a slab on <br /> grade," to read as follows: <br /> "R403.1.6.3 Anchor bolts at the perimeter edge of a slab-on-grade. <br /> Anchor bolts must be hot dipped galvanized in accordance with ASTM <br /> F2329 and have a minimum concrete side cover of 1-1/2 inches unless <br /> provisions have been made to protect the anchor bolts from corrosion." <br /> (41) Subsection R406.1, "Concrete and masonry foundation dampproofing," of the <br /> International Residential Code is deleted in its entirety. <br /> (42) Subsection R406.2, "Concrete and masonry foundation waterproofing," of the <br /> International Residential Code is amended to read as follows: <br /> "R406.2 Concrete and masonry foundation waterproofing. [In areas where <br /> exterior] Exterior foundation walls that retain earth and enclose interior spaces <br /> and floors below grade shall be waterproofed from [the higher of(a)] the top of <br /> the footing [or (b) 6 inches (152 mm) below the top of the basement floor,] to the <br /> finished grade. Walls shall be waterproofed in accordance with one of the <br /> following: <br /> 1. Two-ply hot-mopped felts. <br /> 2. Fifty-five-pound (25 kg) roll roofing. <br /> [3. Six mil (0.15 mm)polyvinyl chloride. <br /> 4. Six mil (0.15 mm) polyethylene. <br /> 5-]3. Forty-mil (1 mm) polymer-modified asphalt. <br /> [6 ]4. Sixty-mil (1.5 mm) flexible polymer cement. <br /> [7,]5. One-eighth-inch (3 mm) cement-based, fiber-reinforced, waterproof <br /> coating. <br /> [8,]6. Sixty-mil (1.5 mm) solvent-free liquid-applied synthetic rubber. <br /> All joints in membrane waterproofing shall be lapped and sealed with an <br /> adhesive compatible with the membrane. <br /> Exception: Organic-solvent-based products such as hydrocarbons, <br /> chlorinated hydrocarbons, ketones and esters shall not be used for ICF walls <br /> with expanded polystyrene form material. Use of plastic roofing cements, <br /> acrylic coatings, latex coatings, mortars and pargings to seal ICF walls is <br /> permitted. Cold-setting asphalt or hot asphalt shall conform to type C of <br /> ASTM D 449. Hot asphalt shall be applied at a temperature of less than <br /> 200°F (93°C)." <br /> 34 <br />
The URL can be used to link to this page
Your browser does not support the video tag.