My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 221 Draft 03 2020-2022
ClerkCouncil
>
Council Records
>
Bills
>
2020-2022
>
BIL 221 Draft 03 2020-2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2023 11:39:00 AM
Creation date
11/18/2022 9:25:20 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2022-2024
Bill/Resolution
221
Draft
03
Introducer
Ashley L. Kierkiewicz, Council Member
Referred To
PWMTC
Action 1
Council: Bill 221, Draft 3 passes first reading; adopts PWMTC-26 - 12/21/22
Action 2
Council: Bill 221, Draft 3 passes second & final reading - 1/5/23
Date To Mayor or Adoption Date
1/10/2023
Reading Number
1
Reading Date
12/21/2022
Ayes
9-Evans, Galimba, Inaba, Kagiwada, Kānealiʻi-Kleinfelder, Kierkiewicz, Kimball, Lee Loy, Villegas
Noes
0
Absent
0
Excused
0
Reading Number .
2
Reading Date .
1/5/2023
Ayes .
9-Evans, Galimba, Inaba, Kagiwada, Kānealiʻi-Kleinfelder, Kierkiewicz, Kimball, Lee Loy, Villegas
Noes .
0
Absent .
0
Excused .
0
Document Relationships
AGE COUNCIL 2022-12-21 2022-2024
(Related To)
Path:
\Council Records\Agendas\2022-2024\Council
AGE COUNCIL 2023-01-05 2022-2024
(Related To)
Path:
\Council Records\Agendas\2022-2024\Council
COM 1029.009 2020-2022
(Related)
Path:
\Council Records\Communications\2020-2022
ORD 2023-008 2022-2024
(Related To)
Path:
\Council Records\Ordinances\2023
REP PWMTC 026 2022/11/15 2020-2022
(Related)
Path:
\Council Records\Reports\2020-2022\Public Works and Mass Transit Committee (PWMTC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(44) Fire protection systems out of service. Section 13.1.10 is amended to read <br /> as follows: <br /> "13.1.10. The AHJ shall be verbally notified immediately when any fire <br /> protection system is out of service and on restoration of service." <br /> [2018 HSFC: 45] <br /> (45) Fire protection systems advanced notification. Sections 13.1.10.1, <br /> 13.1.10.2, and 13.1.10.3 are added to read as follows: <br /> "13.1.10.1 The county fire department shall be given a seventy-two hour <br /> notification prior to a scheduled inspection, testing, maintenance, or retesting of <br /> any fire protection system (including class I, II, and III, and combined systems, <br /> automatic fire sprinkler systems, and other fire extinguishing systems) and fire <br /> alarm systems within their respective jurisdiction in the State." <br /> [2018 HSFC: 46] <br /> "13.1.10.2 Failure to comply with the requirements of this section may result in <br /> the county fire department deeming it an invalid test. A retest may be required <br /> to be performed at the testing company's expense." [2018 HSFC: 46] <br /> "13.1.10.3 The certificate of fitness holder shall immediately notify the county <br /> fire department of any system inspection, testing or maintenance cancellations <br /> or changes to the scheduled date and time." [2018 HSFC: 46] <br /> (46) Fire protection systems inspection, testing, and maintenance labeling. <br /> Sections 13.2.3.3.1, 13.2.3.3.2, 13.2.3.3.2.1, 13.2.3.3.3, 13.2.3.3.3.1, 13.2.3.3.4, <br /> 13.2.3.3.4.1, 13.2.3.3.5, 13.2.3.3.5.1, and 13.2.3.3.5.2 are added to read as <br /> follows: <br /> "13.2.3.3.1 Inspection Label and Collar. An approved label and verification <br /> collar signifying successful passing of the system shall be provided when <br /> inspecting, testing, or maintaining any class I, II, III, and combined standpipe <br /> fire extinguishing system." [2018 HSFC: 47] <br /> "13.2.3.3.2 Five Year Inspection Label. <br /> 13.2.3.3.2.1 Class 1, 11, and III, and combined standpipe fire extinguishing <br /> systems passing a five-year inspection (annual inspection for class Il hoses) shall <br /> have an approved, weatherproof, inspection label affixed to the fire department <br /> connection. If the system does not have a fire department connection, labels <br /> 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.