My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2023-008 2022-2024
ClerkCouncil
>
Council Records
>
Ordinances
>
2023
>
ORD 2023-008 2022-2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:46:54 AM
Creation date
1/18/2023 9:45:58 AM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2022-2024
Year
2023
Ordinance
08
Effective Date
1/13/2023
Document Relationships
BIL 221 Draft 03 2020-2022
(Related)
Path:
\Council Records\Bills\2020-2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"13.5.4.5 The fire department shall be verbally notified immediately of any fire <br /> hydrant determined to be out of service. Fire hydrants deemed to be <br /> permanently inoperable or unusable shall be replaced." [2018 HSFC: 60] <br /> "13.5.4.6 Inspection, test, and maintenance report. An inspection, testing, <br /> and maintenance report entitled"Private Fire Service Mains" available on the <br /> State Fire Council's website and at each county fire department's fire prevention <br /> branch, or a similar report approved by the AHJ, shall be provided to the <br /> property owner or agent within fourteen days after the test." [2018 HSFC: 60] <br /> "13.5.4.7 An electronic copy of the unsatisfactory test report shall be submitted <br /> to the AHJ within five working days of the test. The AHJ shall determine if the <br /> submittal of a satisfactory inspection, test, and maintenance report will be <br /> required." [2018 HSFC: 60] <br /> (60) Annual maintenance record keeping. Section 13.6.4.3.4.1.1 is amended to <br /> read as follows: <br /> "13.6.4.3.4.1.1 The tag or label, as a minimum, shall entail the following: <br /> (1) Removing the previous tag or label; <br /> (2) Indicating the month and year the maintenance was performed; <br /> (3) Type of portable fire extinguisher tested; <br /> (4) Certificate of fitness holder's name and number; <br /> (5) Certificate of fitness holder's company name, address, and contact <br /> information; <br /> (6) Be yellow, at least two and one-fourth of an inch in width, three and one- <br /> fourth of an inch in length, and clearly visible without opening any <br /> cabinets; <br /> (7) Be constructed of a durable material approved by the AHJ; <br /> (8) Be punched with no more than one year and one month of the date of <br /> service; and <br /> (9) Not obstruct the portable fire extinguisher classification or instructions for <br /> use." <br /> [2018 HSFC: 61] <br /> (61) Extinguisher maintenance six-year internal examination label. Section <br /> 13.6.4.3.6.5.3 is amended to read as follows: <br /> "13.6.4.3.6.5.3 The 6-year internal examination label, as a minimum shall, <br /> entail the following: <br /> (1) Removing the previous six-year internal examination label; <br /> 24 <br />