My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2023-008 2022-2024
ClerkCouncil
>
Council Records
>
Ordinances
>
2023
>
ORD 2023-008 2022-2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2023 9:46:54 AM
Creation date
1/18/2023 9:45:58 AM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2022-2024
Year
2023
Ordinance
08
Effective Date
1/13/2023
Document Relationships
BIL 221 Draft 03 2020-2022
(Related)
Path:
\Council Records\Bills\2020-2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(5) Be yellow, at least two and one-fourth of an inch in width, and three and <br /> one-fourth of an inch in length; <br /> (6). Be constructed of a durable material approved by the AHJ; <br /> (7) Be clearly visible without obstructing the visibility or operation of the <br /> system; and <br /> (8) Be punched with no more than one year and one month." <br /> [2018 HSFC: 75] <br /> "13.8.2 Hydrostatic Testing. Every twelve years from the date of <br /> manufacture, stared pressure extinguishing agent cylinders shall be <br /> hydrostatically tested." [2018 HSFC: 75] <br /> "13.8.3 Hydrostatic Testing Label. Stored pressure extinguishing agent <br /> cylinders satisfactorily passing a twelve-year hydrostatic test shall, as a <br /> minimum, have a label attached to the cylinder as follows: <br /> (1) Removal of the previous label. <br /> (2) Indicate the type of system, and month and year the system was tested. <br /> (3) Certificate of fitness holder's name and number. <br /> (4) Certificate of fitness holder's company name, address, and contact <br /> information. <br /> (5) Be yellow, at least two and one-fourth of an inch in width, and three and <br /> one-fourth of an inch in length. <br /> (6) Be constructed of a durable material approved by the AHJ. <br /> (7) Be clearly visible without obstructing the visibility or operation of the <br /> system. <br /> (8) Be punched with no more than one year and one month." <br /> [2018 HSFC: 75] <br /> "13.8.4 The fire department shall be verbally notified immediately of any <br /> systems determined to be out of service. Systems that cannot be utilized for <br /> firefighting operations shall have an inoperable system sign affixed to the <br /> manual activation device. The sign shall remain in place until all repairs have <br /> been made and a satisfactory system test is completed." <br /> [2018 HSFC: 75] <br /> "13.8.5 Inspection, Testing, and Maintenance Report. An inspection, <br /> testing, and maintenance report entitled "Foam Water Sprinkler System", "Other <br /> Fire Protection Systems" available on the State Fire Council's website and at <br /> each county fire department's fire prevention branch, or a similar report <br /> approved by the AHJ shall be provided to the property owner or agent within <br /> fourteen days after the test." [2018 HSFC: 75] <br /> 29 <br />
The URL can be used to link to this page
Your browser does not support the video tag.