My WebLink
|
Help
|
About
|
Sign Out
Home
RES 592 Draft 01 2024-2026
ClerkCouncil
>
Council Records
>
Resolutions
>
2024-2026
>
RES 592 Draft 01 2024-2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/9/2026 3:11:23 PM
Creation date
6/5/2026 3:51:01 PM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
RES
Bill/Resolution - Council Term
2024-2026
Bill/Resolution
592
Draft
01
Introducer
Jennifer Kagiwada, Council Member
Referred To
GOEAC
Action 1
GOEAC-141: Recommended adoption - 06/16/26
Action 2
Council: Adopts Res. 592-26 & GOEAC-141 - 07/08/26
Reading Number
1
Reading Date
7/8/2026
Ayes
9-Galimba, Hustace, Inaba, Kagiwada, Kaneali'i-Kleinfelder, Kierkiewicz, Kimball, Onishi, and Villegas
Noes
0
Absent
0
Excused
0
Document Relationships
AGE COUNCIL 2026-07-08 2024-2026
(Related To)
Path:
\Council Records\Agendas\2024-2026\Council
AGE GOEAC 2026-06-16 2024-2026
(Original Version)
Path:
\Council Records\Agendas\2024-2026\Governmental Operations and External Affairs Committee (GOEAC)
COM 0935.000 2024-2026
(Related)
Path:
\Council Records\Communications\2024-2026
COM 0935.001 2024-2026
(Related)
Path:
\Council Records\Communications\2024-2026
COM 0935.002 2024-2026
(Related)
Path:
\Council Records\Communications\2024-2026
REP GOEAC 141 2026-06-16 2024-2026
(Related)
Path:
\Council Records\Reports\2024-2026\Governmental Operations and External Affairs Committee (GOEAC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
replaced or rehabilitated;(4)identification of assets remaining in critical condition <br /> that have not been repaired, replaced or rehabilitated;(5) identification of assets <br /> newly determined to be in critical condition;(6)proactive rehabilitation and <br /> replacement planning for critical condition assets;(7)detailed cost analysis;and <br /> (8)review of CIP planning to address critical assets. <br /> 12.County Sewage Collection Systems Preventative Maintenance Program:The COH will use <br /> its best efforts to eliminate sewage spills from force mains,pumps stations,gravity lines <br /> and WWTPs.The COH will continue to work toward reducing the number,frequency,and • <br /> duration of spills. <br /> a. Spill Response. By July 1,2024,the COH shall develop and submit a Spill Response <br /> Plan for Force Mains and Gravity Mains.The Spill Response Plan shall be <br /> developed with regional considerations and include:(1)Procedures for immediate <br /> response to contain spills and minimize spill volume;(2)Standard procedures for <br /> estimating spill volume;(3)Standard operating procedures for reporting spills. <br /> • b. Sewer Line Operations and Maintenance Preventative Maintenance Program Plan. <br /> By July 1,2025,the COH shall develop and submit a Sewer Line Operations and <br /> Preventative Maintenance Program Plan.The Sewer Line Plan shall include: <br /> i. Initial Condition Assessment:A condition assessment of all gravity sewer <br /> lines shall be completed by CCTV by October 1,2028.The assessment <br /> shall utilize an industry standard,such as the Pipeline Assessment <br /> process developed by the National Association of Sewer Service <br /> Companies(NASSCO)or similar procedure.The sewer line condition <br /> rating shall be integrated into the AMP.A condition assessment of all <br /> force mains shall be completed by October 1,2030.The COH shall <br /> propose to EPA and DOH which industry standard assessment tool will be <br /> followed within 18 months after the EPA Order is executed. <br /> ii. Regular Inspection/cleaning:A schedule for regular inspections and/or <br /> cleaning for each asset will be established and recorded in the AMS as it <br /> is assessed.The plan will establish what factors are used to determine <br /> the schedule and may include age,construction material,condition,and <br /> the presence of defects.The plan shall also identify priority areas for <br /> more frequent inspections and/or cleaning based on relevant <br /> information, including citizen reports,prior inspections and cleaning,spill <br /> reports,the history of spills,the incidence of problems with fats,oil,and <br /> grease(FOG)and root blockages,and the design and history of the sewer <br /> lines.The COH shall propose to EPA and DOH the inspection schedule . <br /> and frequency for force main inspections and cleaning,where <br /> appropriate,within 6-months of after the initial assessment. • <br /> In re County of Hawai'1,Docket No.CWA-309(a)-24-003:Appendix 1 Page 8 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.