Laserfiche WebLink
Section 17-43. Other appeals. Section 17-20. Minor non-substantive changes. <br /> Changed paragraph enumeration from <br /> (a - c to (1 -(3 . <br /> Section 17-44. Rules; adoption Section 17-21. Adopted language contained in sec. 25- <br /> by board of appeals. 2-24, zoning code. This language is <br /> similar to existin Ian ua e. <br /> Section 17-45 & 17-46. <br /> Reserved. <br /> ARTICLE 3. INSTALLATION REQUIREMENTS. <br /> Section 17-47. Uniform Secs. 17-23 to 17-124. Adopts 1997 edition of the Uniform <br /> Plumbing Code adopted. Plumbing Code (UPC). Format change <br /> throughout to model format used by the <br /> City and County of Honolulu. Each <br /> change in the UPC is now described <br /> and set out in a paragraph rather than a <br /> section. This change was made to <br /> improve the readability of the code. <br /> Other substantive changes are <br /> described se aratel below. <br /> Sec. 17-47, ar. 1 Secs. 17-24 No than e. <br /> Sec. 17-47, ar. 2 Secs. 17-25 No than e. <br /> Sec. 17-47, ar. 3 Secs. 17-26 No than e. <br /> Sec. 17-47, ar. 4 Secs. 17-27 No than e. <br /> Sec. 17-47, par. (5) This Section did not exist in The 1997 edition of the International <br /> Secs. 17-23 to 17-124 Plumbing Code (IPC) may be used in <br /> lieu of the Uniform Plumbing Code <br /> when approved by the administrative <br /> authori <br /> Sec. 17-47, par. (8) This Section did not exist in Amending Section 31.2 by changing the <br /> Secs. 17-23 to 17-124 second sentence to read: "No piping <br /> shall be directly embedded in concrete <br /> or masonry unless provisions are made <br /> to protect the piping from damage <br /> resulting from expansion, contraction <br /> and structural settlement." <br /> Sec. 17-47, ar. 9 Secs.17-34 No than e. <br /> Sec. 17-47, par. (10) This Section did not exist in Deleting Section 314.8. Only one <br /> Secs. 17-23 to 17-124 support is required within eighteen <br /> inches of the 'aint. <br /> Sec. 17-47, par. (11) This Section did not exist in All plumbing piping supports shall be <br /> Secs. 17-23 to 17-124 designed and installed for the seismic <br /> forces in accordance with the building <br /> code. <br /> Sec. 17-47, par, 12) This Section did not exist in Deleting Sections 318.0 8 319.0. The <br /> Secs. 17-23 to 17-124 requirements are covered in Dept. of <br /> Health (DOH) Chapter 12, Food <br /> Establishment Sanitation 11-12-21. <br /> Sec. 17-47, par (13) This Section did not exist in Amending Section 402.1 by adding to <br /> Secs. 17-23 to 17-124 the endof the sentence: "but shall not <br /> exceed the requirements of Section <br /> 402.3." <br /> <br /> Sec. 17-47, par (14) This Section did not exist in Deleting Section 402.2 Flush volumes <br /> Secs. 17-23 to 17-124 for low consumption and water saver <br /> water closets and urinals.... <br /> 4 <br /> <br />