<br /> Sec. 17-47, par. (15) Sec. 17-68 Section 402.3.1 Water supply faucets <br /> or valve Amended last part of <br /> sentence to read "...lavatory faucets <br /> shall be provided with such flow control <br /> devices which limit flow to a maximum <br /> of two and one-half (2.5) gallons per <br /> minute at ei h 80 si. <br /> <br /> Sec. 17-47, par. (16) This Section did not exist in Amending Section 408.6 by changing <br /> Secs. 17-23 to 17-124 the third sentence to read: n "The clear <br /> space in front of any water closet, bidet <br /> and lavatory, shall not be less than <br /> twenty-four (24) inches (610 mm) which <br /> may include adjoining floor area." <br /> Sec. 17-47, par. (17) This Section did not exist in Deleting Section 412.2. Location of <br /> Secs. 17-23 to 17-124 Floor Drains. <br /> Sec. 17-47, par. (18) This Section did not exist in Deleting Sections 413.0 to 413.7 <br /> Secs. 17-23 to 17-124 Minimum Number of Required Fixtures. <br /> <br /> Sec. 17-47, par. (19) Sec. 17-48 Adding "Exception: Tub-mounted hand- <br /> held shower heads do not require an <br /> anti-scald valve." <br /> Sec. 17-47, ar. 20 Sec. 17-114 No than e. <br /> Sec. 17-47, ar. 21 Sec. 17-115 No than e. <br /> Sec. 17-47, ar. 22 Sec. 17-116 No than e. <br /> Sec. 17-47, par. (23) This Section did not exist in Amending Section 507.3.1 by adding to <br /> Secs. 17-23 to 17-124 the end thereof: "The upper combustion <br /> air duct shall extend horizontally or <br /> upwards to the outside of the <br /> enclosure." <br /> Sec. 17-47, par. (24) This Section did not exist in Amending Section 507.3.3 and 507.3.5 <br /> Secs. 17-23 to 17-124 by changing the first word from <br /> "O enin s" to "Ducts." <br /> Sec. 17-47, par. (25) Sec. 17-117 Amending Section 510.1 by adding <br /> exception "(2) Fuel burning water <br /> heaters having sealed combustion <br /> chambers may be installed at floor level. <br /> (3) Electric) water heaters in garages <br /> may be installed at floor level." <br /> Sec. 17-47, par. (26) This Section did not exist in Amending Section 511.0 by changing <br /> Secs. 17-23 to 17-124 the first sentence to read: "Every water <br /> heater, clothes washer and clothes <br /> dryer installation should have a working <br /> space of not less than thirty (30) inches <br /> (762 mm) in front of such appliance for <br /> inspection, repair, or replacement. <br /> Sec. 17-47, par (27) This Section did not exist in Amending Section 511.2 by changing <br /> Secs. 17-23 to 17-124 the first sentence to read: "Every attic, <br /> roof, mezzanine, or platform more than <br /> sixteen (16) feet (4.9 meters) above the <br /> ground floor level shall be accessible by <br /> a stairway or ladder permanently <br /> fastened to teh buildin <br /> Sec. 17-47, ar 28 Sec. 17-118 No Chan e. <br /> 5 <br /> <br />