Laserfiche WebLink
Community: Hawaii County State: Hawaii Level of Regulations: a b c d e <br /> Item Description State Model Applicable <br /> (Section reference of NFIP Regulations follows) Ordinance Section Ordinance Section <br /> . • - . . . . .r <br /> • .r ~ ~ .r <br /> 41. In V I-30, VE, and V Zones, obtain and maintain the elevation of the Section 27-16(b)(6) <br /> bottom of the lowest structural member of the lowest floor of all <br /> new and substantial im oved structures. 60.3 e 2 <br /> 42. In V1-30, VE, and V Zones, require that all new construction and Section 27-23(b) <br /> substantial improvements: <br /> (a) Are elevated and secured to anchored pilings or columns so that <br /> the lowest portion of the lowest horizontal structwal member is <br /> at or above the BFE. 603 a (4 <br /> (b) A registered professional engineer/architect certify that the Section 27-23(g) <br /> design and methods of construction meet elevation and <br /> anchorin re uirements ate 4 i and ii . 603 e 4 <br /> (c) Have the space below the lowest floor constructed with Section 27-23(d) <br /> breakaw walls or left o 603(ex <br /> (d) All new construction is landward or mean high tide. Section 27-23(c) <br /> 60.3 e 3 <br /> (e) Prohibit use of fill for structural support. [60.3(e)(6)] Section 27-23(e) <br /> (f) Prohibit alteration of sand dunes and mangrove stands which Section 27-23(f) <br /> would increase tential flood d e. 60.3(e 7) <br /> 43. Require that manufactured homes placed or substantially improved NOTE: Item 4S is not required if community <br /> within V I-30, VE, and V Zones, which meet one of the following requires all manufactured homes meetthe V <br /> location criteria, meet the V Zone standazds in Zone standards 1988 r ulations . <br /> 603(ex2) through (ex7): Section 27-21(d) <br /> i. outside a manufactured home pazk or subdivision; <br /> ii. in a new manufactured home pazk or subdivision; <br /> iii. in an expansion to an existing manufactwed home park or <br /> subdivision; <br /> iv. on a site in an existing pazk which a manufactured home has <br /> incurred substantial dam a as a result of flood. 60.3(e)(S) <br /> <br /> 44. In V ]-30, VE and V Zones, require that manufactured homes to be NOTE: Item 44 is not required if community <br /> placed or substantially improved in an existine manufactured home requires all manufactured homes meetthe V <br /> part to be elevated so that: Zone standards 1986 re ulations . <br /> i. the lowest floor is at or above the BFE, or Section 27-21 (d) <br /> ii. the chassis is supported by reinforced piers no less than 36 <br /> inches above rade and secure] anchored. [60.3(e (9) <br /> <br /> 45. Tn V 1-30, VE, and V Zones, all recreational vehicles to be Section 27-33 <br /> placed on a site must be elevated and anchored or be on the (see : evie„ comments <br /> site for less than ] 80 consecutive days or be fully licensed <br /> and hi hwav ready. 603(e)(9 <br /> Face 5 of 6 <br /> <br />