My WebLink
|
Help
|
About
|
Sign Out
Home
COM 1017.000 1996-1998
ClerkCouncil
>
Council Records
>
Communications
>
1996-1998
>
COM 1017.000 1996-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2008 10:51:36 PM
Creation date
5/10/2008 8:15:31 PM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
1996-1998
Communication
1017
Point
000
Author
Thomas E. Arizumi, P.E., Chief, Environmental Management Division
Communications - Referred To
PWPC
Comments
PWPC: Close file - 10/20/98
Communications - File Code
SEW
Document Relationships
AGE PWPC 10/20/1998 1996-1998
(Related)
Path:
\Council Records\Agendas\1996-1998\Public Works & Parks Committee (PWPC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br /> <br /> <br /> <br /> CURRENT INSPECTION <br /> <br /> 1. Maintenance: Check either: No. of: <br /> <br /> Preventive Maintenance: x Current - Backlogged <br /> Corrective Maintenance: x Satisfactory - Excessive <br /> Major (or all) items requiring repair/replacement: <br /> <br /> None. <br /> <br /> 2. Reuse: <br /> The facility has a DOH approved effluent irrigation plan: <br /> Yes No x Not applicable <br /> <br /> 3. NPDES or Chapter 62 violations (effluent limitations, spills, etc.): <br /> <br /> None <br /> 4. Visual quality of effluent on date of inspection (inspector's judgment): <br /> <br /> The effluent was noted to be clear on the date of the inspection. <br /> <br /> 5. Laboratory Data: <br /> The following influent and effluent data were collected for the period <br /> July 1997 through June 1998: <br /> <br /> a. Influent BOD5 and TSS averaged 183 mg/l and 198 mg/1, respectively. <br /> <br /> b. Effluent BOD5 averaged 2.4 mg/l and effluent TSS averaged 2.5 mg/1. <br /> 6. Facility's Present Deficiencies: <br /> <br /> 1. Excessive rust was noted on the blowers. <br /> <br /> 2. The effluent flow meter was reportedly calibrated but did not have <br /> a calibration tag. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> O&M Report Form (12/93) 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.