My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 111 Draft 01 1996-1998
ClerkCouncil
>
Council Records
>
Bills
>
1996-1998
>
BIL 111 Draft 01 1996-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2021 8:21:07 AM
Creation date
4/2/2009 10:46:39 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
1996-1998
Bill/Resolution
111
Draft
01
Introducer
Dominic Yagong, Council Member
Referred To
PWPC
Action 1
PWPC-55: Recommends passage of Bill 111 on 1st reading - 07/22/97
Action 2
Council: Passes Bill 111 on 1st reading and adopts PWPC-55 - 08/06/97
Action 3
Council: Passes Bill 111 on 2nd & final reading - 08/20/97
Status
Adopted
Date To Mayor or Adoption Date
8/21/1997
Reading Number
1
Reading Date
8/21/1997
Ayes
9-Arakaki; Chung; Leithead-Todd; Ray; Reynolds; Santangelo; Smith; Tyler; Yagong
Noes
0-
Absent
0-
Excused
0-
Reading Number .
2
Reading Date .
8/20/1997
Ayes .
8-Arakaki; Chung; Leithead-Todd; Ray; Reynolds; Smith; Tyler; Yagong
Noes .
0-
Absent .
1-Santangelo
Excused .
0-
Document Relationships
COM 0387.000 1996-1998
(Related)
Path:
\Council Records\Communications\1996-1998
ORD 1997-116 1996-1998
(Related)
Path:
\Council Records\Ordinances\1997
REP PWPC 055 07/22/1997 1996-1998
(Related)
Path:
\Council Records\Reports\1996-1998\Public Works & Parks Committee (PWPC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. <br /> <br />. <br /> <br />(B) For nonresidential new construction and substantial <br />improvements: <br />If the lowest floor[, but not including floors used <br />solely for vehicle parking, building access, or storage,] is <br />below the elevation referenced in <br />subsection 27-18(d)(2)(A), then the [lowest floor] structure <br />together with attendant utility and sanitary facilities, shall <br />be designed and constructed such that: <br />(i) The structure is watertight below the referenced <br />flood elevation. <br />(ii) The walls are substantially impermeable to the <br />passage of water. <br />(iii) The structural components are capable of resisting <br />hydrostatic and hydrodynamic loads and the effects <br />of buoyancy. <br />(C) New construction and substantial improvement shall be <br />required to provide adequate drainage paths around <br />structures on slopes to guide flood waters around and away <br />from proposed structures. <br />(3) Within Zones V and VE: <br />New construction and substantial improvement shall <br />comply with the standards of section 27-23. <br />(4) Within Zone A: <br />New construction and substantial improvement shall <br />comply with the standards of section 27-24. <br /> <br />SECTION 4. Material to be repealed is bracketed. New material is underscored. In <br /> <br />printing this ordinance, the brackets, bracketed material and underscoring need not be included. <br /> <br />SECTION 5. If any provision of this ordinance, or the application thereof to any person <br /> <br />or circumstance, is held invalid, such invalidity shall not affect other provisions or applications <br /> <br />of the ordinance which can be given effect without the invalid provision or application, and to <br /> <br />this end, the provisions of this ordinance are declared to be severable. <br /> <br />-4- <br />