My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0876.002 2008-2010
ClerkCouncil
>
Council Records
>
Communications
>
2008-2010
>
COM 0876.002 2008-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2010 2:58:26 PM
Creation date
7/23/2010 9:31:10 AM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2008-2010
Communication
0876
Point
002
Author
Emily I. Naeole-Beason, Council Vice Chair
Communications - Referred To
PWIRC
Comments
Council: Close file - 09/09/10
Document Relationships
AGE COUNCIL 09/09/2010 2008-2010
(Related To)
Path:
\Council Records\Agendas\2008-2010\Council
AGE PWIRC 08/03/2010 2008-2010
(Related)
Path:
\Council Records\Agendas\2008-2010\Public Works & Intergovernmental Relations Committee (PWIRC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
span. A minimum 3 /4 -inch air gap must also be <br />provided between the radiant barrier and the ceiling <br />or insulation below. <br />2.2 The radiant barrier shall be stretched with the shiny <br />side facing down between the top cords of the truss <br />and stapled or otherwise secured at each side. A <br />minimum air space of 3 /4 -inch above and below is <br />required. <br />2.3 For attic installations only, the radiant barrier shall <br />be stapled or otherwise secured to the bottom <br />surface of the top cord of the truss and draped <br />below with the shiny side facing down. A minimum <br />air space of 3 /4 -inch above and below is required. <br />2.4 For open beam ceiling construction only, the radiant <br />barrier shall be laid on top of the roof deck with the <br />shiny side facing up and a minimum 3 /4 -inch air gap <br />between the radiant barrier and the roofing material <br />above. The roof slope must be greater than or equal <br />to 14' from horizontal. <br />3. At least one (1) square foot of free area for ventilation shall <br />be provided per 150 square feet of attic floor area, or in the <br />case of vaulted or open beam ceilings, per 150 square feet <br />of ceiling area. In vaulted or open beam ceilings, the air <br />space shall be vented with vent area approximately evenly <br />distributed between the top and bottom. In vaulted ceiling, <br />vents shall be provided for each air space between rafters." <br />(16) Amending Table 402.1.1. Table 402. 1.1 is amended by deleting all <br />references to Climate Zones 1 through 8 and replacing with a single <br />climate zone, "Hawai`i County ", amending footnotes "a" and "b ", and <br />deleting footnotes "c" through 'J", to read as follows: <br />"TABLE 402.1.1 <br />INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT' <br />Climate Zone <br />Hawaii County <br />Fenestration U- Factor b <br />1.20 <br />Skylight U- Factor <br />0.75 <br />Glazed Fenestration SHGC <br />0.30 <br />Ceiling R -Value <br />See Section 402.1.1.1 <br />Wood Frame Wall R -Value <br />13 <br />Mass Wall R -Value <br />3 <br />Floor R -Value <br />NR <br />Basement Wall R -Value <br />NR <br />Slab R -Value & Depth <br />NR <br />Crawl Space Wall R -Value <br />NR <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.