Laserfiche WebLink
(35) Amending Table K -2. Appendix K is amended by amending Table K -2, <br /> Capacity of Septic Tanks, as follows: <br /> A) Under column "Single- Family Dwellings- Number of Bedrooms ", <br /> delete "1 or 2 and 3" and replace with "4 or less "; also delete "or <br /> 6" from "5 or 6 ". <br /> B) Under column "Multiple Dwelling Units or Apartments -One <br /> Bedroom Each ", delete "3 through 10 ". <br /> C) Delete entire column "Other Uses: Maximum Fixture Units Served <br /> per Table 7 -3 ". <br /> D) Under "Minimum Septic Tank Capacity in Gallons /Liters" delete <br /> the first two rows, amend the third and fourth rows, and delete <br /> rows five through eleven. <br /> E) Delete " *Note: Extra Bedroom, 150 gallons (568 liters) each. <br /> Extra dwelling units over 10: 250 gallons (946 liters) each. Extra <br /> fixture units over 100: 25 gallons (95 liters) per fixture unit." <br /> As amended, Table K -2 shall read: <br /> "TABLE K -2 <br /> Capacity of Septic Tanks <br /> Single - Family Multiple Dwelling Minimum <br /> Dwellings — Units or Septic Tank <br /> Number Apartments — One Capacity in <br /> of Bedrooms Bedroom Each Gallons (Liters) <br /> 4 or less -- 1,000 (3,785) <br /> 5 2 units 1,250 (4,731) <br /> Septic tank sizes in this table include sludge storage capacity and the connection of domestic <br /> food waste disposal units without further volume increase." <br /> 17 <br />