My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2011-070 2010-2012
ClerkCouncil
>
Council Records
>
Ordinances
>
2011
>
ORD 2011-070 2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2011 2:19:56 PM
Creation date
8/23/2011 4:27:26 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2010-2012
Year
2011
Ordinance
070
Effective Date
11/15/2011
Document Relationships
BIL 269 Draft 03 2008-2010
(Related)
Path:
\Council Records\Bills\2008-2010
BIL 269 Draft 03 2008-2010
(Related To)
Path:
\Council Records\Bills\2008-2010
COM 0127.002 2010-2012
(Related)
Path:
\Council Records\Communications\2010-2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(B) Standards for a mini -leach field system: <br />(1) Perforated sections shall be a minimum three (3) inch (80 mm) <br />diameter and shall be constructed of perforated high- density <br />polyethylene pipe, perforated ABS pipe, perforated PVC pipe, or other <br />approved materials, provided that sufficient openings are available for <br />distribution of the gray water in to the trench area. Material, <br />construction, and perforation of the pipe shall be in compliance with the <br />appropriate absorption fields drainage piping standards and shall be <br />approved by the Health Officer. <br />(2) Filter material, clean stone, gravel, slag, or similar filter material <br />acceptable to the authority having jurisdiction, varying in size from <br />three - quarter (3/4) inch (20 mm) to two and one -half (2 -1/2) inch (65 <br />mm) shall be placed in the trench to the depth and grade required by <br />this section. The perforated section shall be laid on the filter material in <br />an approved manner. The perforated section shall then be covered with <br />filter material to the minimum depth required by this section. The filter <br />material shall then be covered with untreated building paper, straw, or <br />similar porous material to prevent closure of voids with earth backfill. <br />No earth backfill shall be placed over the filter material cover until after <br />inspection and acceptance." <br />(21) Deleting Chart for Section 1611.0 (C). The corresponding chart for Section <br />1611.0 (C) is deleted. <br />(22) Amending Section 1612.0 (A). Section 1612.0 (A) is amended to read: <br />"(A) Other collection and distribution systems such as laundry only gray water <br />systems may be approved by the local Health Officer." <br />(23) Amending Table 16 -1. Table 16 -1, Location of Gray Water Systems, is amended as <br />follows: <br />A) Deleted "100% expansion area" as relating to "Disposal Field." <br />B) Changed the values for the following Irrigation/Disposal Field: <br />Building Structures <br />Water Supply Wells <br />Disposal Field <br />11 <br />