My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2012-003 2010-2012
ClerkCouncil
>
Council Records
>
Ordinances
>
2012
>
ORD 2012-003 2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2012 1:15:33 PM
Creation date
1/24/2012 4:09:07 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2010-2012
Year
2012
Ordinance
003
Effective Date
1/17/2012
Document Relationships
BIL 139 Draft 02 2010-2012
(Related)
Path:
\Council Records\Bills\2010-2012
BIL 139 Draft 02 2010-2012
(Related To)
Path:
\Council Records\Bills\2010-2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(2) Fire Department Connections (FDC) to alternative water supplies shall <br />comply with 18.3.8 (1) -(6) of this code. <br />(3) In that water catchment systems are being used as a means of water supply <br />for firefighting, such systems shall meet the following requirements: <br />(a) In that a single water tank is used for both domestic and <br />firefighting water, the water for domestic use shall not be capable <br />of being drawn from the water reserved for firefighting. <br />(b) Minimum pipe diameter sizes from the water supply to the Fire <br />Department Connection (FDC) shall be as follows: <br />i. 4" for C900 PVC pipe. <br />ii. 4" for C906 PE pipe. <br />iii. 3" for ductile Iron. <br />iv. 3' for galvanized steel. <br />(c) The Fire Department Connection shall: <br />i. Be made of galvanized steel. <br />ii. Have a gated valve with 2 -1/2 inch, National Standard <br />Thread male fitting and cap. <br />iii. Be located between 8 ft and 16 ft from the Fire department <br />access. The location shall be approved by the AHJ; <br />iv. Not be located less than 18 inches, and no higher than 36 <br />inches from finish grade, as measured from the center of <br />the FDC orifice. <br />v. Be secure and capable of withstanding drafting operations. <br />Engineer stamped plans may be required. <br />vi. Not be located more than 150 feet of the most remote part, <br />but not less than 20 feet, of the structure being protected. <br />vii. Also comply with section 13.1.3 and 18.2.3.4.6.1 of this <br />code. <br />(d) Commercial buildings requiring a fire flow of 2000 gpm shall be <br />provided with a second FDC. Each FDC shall be independent of <br />each other, with each FDC being capable of flowing 500gpm by <br />engineered design standards. The second FDC shall be located in <br />an area approved by the AHJ with the idea of multiple Fire <br />apparatus' conducting drafting operations at once, in mind. <br />(e) Inspection and maintenance shall be in accordance to NFPA 25. <br />(f) The owner or lessee of the property shall be responsible for <br />maintaining the water level quality, and appurtenances of the <br />system. <br />(4) Exceptions to Section 26 -42. <br />(a) Agricultural buildings, storage sheds, and shade houses with no <br />combustible or equipment storage. <br />(b) Buildings less than 800 square feet in size that meets the minimum <br />Fire Department Access Road requirements. <br />(c) For one and two family dwellings, agricultural buildings, storage <br />- sheds, and detached garages 800 to 2000 square feet in size that <br />meets the minimum Fire Department Access Road requirements, <br />
The URL can be used to link to this page
Your browser does not support the video tag.