My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2012-003 2010-2012
ClerkCouncil
>
Council Records
>
Ordinances
>
2012
>
ORD 2012-003 2010-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2012 1:15:33 PM
Creation date
1/24/2012 4:09:07 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2010-2012
Year
2012
Ordinance
003
Effective Date
1/17/2012
Document Relationships
BIL 139 Draft 02 2010-2012
(Related)
Path:
\Council Records\Bills\2010-2012
BIL 139 Draft 02 2010-2012
(Related To)
Path:
\Council Records\Bills\2010-2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the distance to the Fire Department Connection may be increased <br />to 1000 feet. <br />(d) For one and two family dwellings, agricultural buildings and <br />storage sheds greater than 2000 square feet, but less than 3000 <br />square feet of living area, that meets the minimum Fire <br />Department Access Road requirements, the distance to the Fire <br />Department Connection may be increased to 500 feet. <br />(e) For buildings with an approved automatic sprinkler system, the <br />minimum water supply required may be modified. <br />Section 26 -43. Occupant Load Sign for Assemblies. <br />20.1.4.10.3.1 is amended to read: <br />20.1.4.10.3.1 Any room or area constituting an assembly, regardless of seating <br />arrangements, shall have a permanent occupant load sign posted in a conspicuous <br />place near the main exit from the room. <br />Section 26 -44. Seating arrangements. <br />20.1.4.10.4 is added to read: <br />20.1.4.10.4 The maximum number of seats permitted between the farthest seat <br />and any aisle shall not exceed that shown in table 20.1.4.10.4. <br />Table 20.1.4.10.4 <br />Application <br />Outdoors <br />Indoors <br />Chair style seating (loose) <br />Bench/ Bleacher type seating <br />11 <br />20 <br />6 <br />9 <br />Section 26 -45. Cooking Operations affiliated with Tents and Temporary structures. <br />25.1.11.1 is added to read: <br />25.1.11.1 Cooking operations shall comply with Section 10.11.3.1 of this code. <br />Section 26 -46. Deep Fat Frying. <br />25.1.11.2 is added to read: <br />25.1.11.2 A minimum of one Type K Fire extinguisher shall be accessible within <br />30 feet of any deep fat frying operation in accordance with NFPA 10. <br />17 <br />