My WebLink
|
Help
|
About
|
Sign Out
Home
RES 264 Draft 01 2012-2014
ClerkCouncil
>
Council Records
>
Resolutions
>
2012-2014
>
RES 264 Draft 01 2012-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2020 10:50:50 AM
Creation date
12/30/2013 8:42:41 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
RES
Bill/Resolution - Council Term
2012-2014
Bill/Resolution
264
Draft
01
Introducer
Dru Mamo Kanuha, Council Member
Referred To
COUNCIL
Action 1
Council: Adopts Res. 264-14 - 01/22/14
Status
Adopted
Date To Mayor or Adoption Date
1/22/2014
Reading Number
1
Reading Date
1/22/2014
Ayes
8-Eoff;Ford;Ilagan;Kern;Onishi;Poindexter;Wille;Yoshimoto
Noes
0
Absent
1-Kanuha
Excused
0
Document Relationships
AGE COUNCIL 2014/01/22 2012-2014
(Related To)
Path:
\Council Records\Agendas\2012-2014\Council
COM 0591.000 2012-2014
(Related To)
Path:
\Council Records\Communications\2012-2014
NTC COU PUBLIC HEARING 2014-03-18 2012-2014 RE SID LONO KONA
(Related To)
Path:
\Council Records\Notices\2012-2014\Council
NTC COU PUBLIC HEARING 2014-11-18 2012-2014 RE SID LONO KONA
(Related To)
Path:
\Council Records\Notices\2012-2014\Council
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C. Material to be Used. The materials to be used in the construction and <br />installation of the special improvements are set forth in the Director's Report, and <br />include, without limitation, the following: <br />i. 5,640 Lin. Ft., 8 -inch PVC SDR -26 sewer pipe and fittings; <br />ii. 360 Lin. Ft., 10 -inch PVC SDR -26 sewer pipe and fittings; <br />ill. 29 Each, sewer manholes 5.0' to 9.5' deep; <br />iv. 4 Each, lined shallow drop sewer manholes 10.0' to 14.99' deep; <br />V. 1 Each, lined drop sewer manholes 15.00' to 20.00' deep; and <br />vi. 110 Each, sewer lateral connection. <br />d. Proposed Assessment Unit; Method of Assessment; Minimum Number of <br />Installments, Preliminary Assessment Roll. <br />i. Assessment Unit. "Assessment unit" for purposes of the Improvement <br />District shall mean a duly subdivided parcel of land or condominium unit bearing <br />a unique tax map key number. <br />ii. Method of Assessment. <br />(1) As used in this Resolution, "Net Project Costs" means the <br />Project Costs, less any amounts which reduce the actual costs of the <br />special improvements to the County. By way of example, assuming the <br />Project Costs to be $6,461,800 as set forth in the Director's Report, and <br />further assuming an RUS grant of $4,024,800 t o be applied against the <br />Project Costs, the Net Project Costs would be $2,437,000. The Net <br />Project Costs are equivalent to the RUS loan amount. <br />(2) Each assessment unit existing as of the date that <br />assessments begin to accrue on assessment units within the Improvement <br />District (the "Commencement Date") shall be subject to an assessment <br />calculated by (A) dividing the Net Project Costs by the total number of <br />single-family equivalent (SFE) represented by all assessment units in the <br />Improvement District, and (B) with respect to each assessment unit, <br />multiplying the amount determined pursuant to (A) above by the number <br />11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.