My WebLink
|
Help
|
About
|
Sign Out
Home
COM 0888.000 2014-2016
ClerkCouncil
>
Council Records
>
Communications
>
2014-2016
>
COM 0888.000 2014-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2016 10:23:29 AM
Creation date
5/18/2016 11:30:12 AM
Metadata
Fields
Template:
Communications
Communications - Type
COM
Communications - Council Term
2014-2016
Communication
0888
Point
000
Author
William P. Kenoi, Mayor
Communications - Referred To
PC
Document Relationships
BIL 209 Draft 01 2014-2016
(Related To)
Path:
\Council Records\Bills\2014-2016
REP PC 066 2016/06/02 (2014-2016)
(Related To)
Path:
\Council Records\Reports\2014-2016\Planning Committee (PC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
85
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,SOF WLi Ffl+�g.. <br /> pEj4,1 <br /> • <br /> `i • <br /> ,91 <br /> DEPARTMENT OF WATER SUPPLY • COUNTY OF HAWAII <br /> V- Fs >1HP��. 345 KEKUANAO'A STREET, SUITE 20 • HILO. HAWAII 96720 <br /> AW , <br /> TELEPHONE (808) 961 -8050 • FAX (808) 961-8657 <br /> November 25, 2015 <br /> Mr. Peter Dahlberg <br /> Aina Engineers Inc. <br /> P.O. Box 81 <br /> Hulualoa, HI 96725 <br /> Dear Mr. Dahlberg: <br /> Subject: Water Usage Calculations for Apartment Building and Commercial Kitchen <br /> Change of Zone Ordiance No. 03-115 <br /> Applicant—Tante Urban <br /> Tax Map Key 7-5-022:040 <br /> We have reviewed the subject estimated water usage calculations and find them acceptable. Based on <br /> the estimated maximum daily usage of 4,298 gallons per day (GPD), the proposed development will <br /> require eight (8) units of water, at a maximum of 600 GPD per unit. A 1V2-inch meter should be <br /> adequate to support that demand for the proposed project. <br /> Pursuant to Rule 5 of the Department's Rules and Regulations, a water commitment may be issued. <br /> Based on the seven(7) additional units of water needed (one (1) unit of water allotted through an <br /> existing 5/8-inch water meter), the required water commitment deposit is $150.00 per additional unit, <br /> or$1,050.00. Remittance of the water commitment deposit is requested as soon as possible so that a <br /> water commitment may be formally effected. The commitment will be in writing with specific dates <br /> and conditions stated. Upon receipt of the water commitment deposit, we will provide our <br /> requirements for water service, applicable facilities charges due, and other conditions for final <br /> approval. <br /> The commercial zoning requires the installation of a reduced pressure type back-flow prevention <br /> assembly (BFP) within five(5) feet of the meter on private property. The installation of the backflow <br /> prevention assembly must be inspected and approved by the Department. <br /> The Department's Water System Standards require that a minimum of 2,000 GPM be available at the <br /> site for fire protection for commercial zoning. Please be informed that the nearest fire hydrant is <br /> connected to a 6-inch waterline. within Kalawa Street, which is inadequate to provide the required fire <br /> flow. The applicant should contact the Fire Department to determine any other fire protection <br /> requirements. <br /> . .`Ybrater, Our Most Precious Resource . . , Ka Wai,r4 pane . . . <br />
The URL can be used to link to this page
Your browser does not support the video tag.