Laserfiche WebLink
banking functions at this site. In so doing, it would give the bank <br /> the option to either relocate some of its operations or to provide <br /> another branch that would be proximate to the University and this <br /> area of the community. <br /> The visibility and accessibility of this area make this site quite <br /> attractive for office use. At the same time, because of some of the <br /> surrounding residences, the proposed office or bank use would be <br /> more benign and less noxious than a retail or light industrial activity. <br /> If the request is approved, the Applicant would construct a single- <br /> story office building, consisting of approximately 7,500 square feet. <br /> The height of the structure is not expected to exceed forty-five (45) <br /> feet, the maximum allowable by the Zoning Code. While higher <br /> than normal for a single-story building, this added height is <br /> designed to provide for the option to accommodate a mezzanine <br /> within the structure to accommodate office and related uses. <br /> (Figure 4) <br /> As proposed, there would be a minimum of thirty six (36) parking <br /> stalls, including two (2) handicapped stalls, provided on-site. This <br /> would be more than the Zoning Code's parking requirement of <br /> twenty five (25) stalls for a 7,500+/- square foot building, as it would <br /> provide some accommodation for employee parking. (Figure 3) <br /> The Zoning Code requires a minimum setback of fifteen (15) feet <br /> from the front OR rear yard; and none forthe side yard, except <br /> where it adjoins a residential zone, in which case the residential <br /> zone setbacks must be used. In this case, the adjoining properties <br /> are zoned RS-10, and the setbacks are ten (10) feet. <br /> As proposed, the building would be setback no less than twenty <br /> (20) feet from Lanikaula Street and no less than thirty five (35) feet <br /> from Kinoole Street. Along the sides, the setbacks would be in <br /> excess of forty (40) feet. As such, the setbacks would be <br /> consistent with the Code. <br /> There would be two (2) full-movement accesses, one from Kinoole <br /> Street and the other from Lanikaula Street. They would be <br /> positioned furthest from the intersection. There will also be a drive- <br /> through ATM, with ingress from Lanikaula Street and egress at <br /> Kinoole Street <br /> Landscaping consistent with Planning Department Rule Na. 17 <br /> would be installed around the perimeter of the subject site. <br />