My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2020-010 2018-2020
ClerkCouncil
>
Council Records
>
Ordinances
>
2020
>
ORD 2020-010 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 1:36:10 PM
Creation date
2/5/2020 1:34:55 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2018-2020
Year
2020
Ordinance
010
Effective Date
2/4/2020
Document Relationships
BIL 126 Draft 01 2018-2020
(Related)
Path:
\Council Records\Bills\2018-2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
setpoint to 90° F or greater within five minutes of the door opening. Mechanical <br /> cooling may remain enabled if the outdoor air temperature is below the space <br /> temperature." <br /> (15) Subsection C405.2 of the International Energy Conservation Code is amended to read <br /> as follows: <br /> "C405.2 Lighting controls (Mandatory). Lighting systems shall be provided with <br /> controls as specified in Sections C405.2.1, C405.2.2, C405.2.3, C405.2.4 and <br /> C405.2.5. <br /> Exceptions: Lighting controls are not required for the following: <br /> 1. Areas designated as security or emergency areas that are required to be <br /> continuously lighted. <br /> 2. Interior exit stairways, interior exit ramps and exit passageways. <br /> 3. Emergency egress lighting that is normally off. <br /> 4. Spaces where the designed lighting power densities are less than 70% of <br /> the lighting power densities specified in Table C405.4.2(1) and Table <br /> C405.4.2(2)." <br /> (16) Subsection C405.2.4 of the International Energy Conservation Code is amended to <br /> read as follows: <br /> "C405.2.4 Specific application controls. Specific application controls shall be <br /> provided for the following: <br /> 1. Display and accent light shall be controlled by a dedicated control that is <br /> independent of the controls for other lighting within the room or space. <br /> 2. Lighting in cases used for display case purposes shall be controlled by a <br /> dedicated control that is independent of the controls for other lighting within <br /> the room or space. <br /> 3. Hotel and motel sleeping units [and],guest suites, and time-share <br /> condominiums shall have a master control device that is capable of <br /> automatically switching off all installed luminaires and switched receptacles <br /> within 20 minutes after all occupants leave the room. <br /> Exception: Lighting and switched receptacles controlled by captive key <br /> systems. <br /> 4. Supplemental task lighting, including permanently installed under-shelf or <br /> under-cabinet lighting, shall have a control device integral to the luminaires or <br /> be controlled by a wall-mounted control device provided that the control <br /> device is readily accessible. <br /> 5. Lighting for nonvisual applications, such as plant growth and food warming, <br /> shall be controlled by a dedicated control that is independent of the controls <br /> for other lighting within the room or space. <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.