My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2020-010 2018-2020
ClerkCouncil
>
Council Records
>
Ordinances
>
2020
>
ORD 2020-010 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 1:36:10 PM
Creation date
2/5/2020 1:34:55 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2018-2020
Year
2020
Ordinance
010
Effective Date
2/4/2020
Document Relationships
BIL 126 Draft 01 2018-2020
(Related)
Path:
\Council Records\Bills\2018-2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHGCb <br /> Orientations SEW N <br /> PF <0.2 0.25 0.33 <br /> 0.2 <PF < 0.5 0.30 0.37 <br /> PF> 0.5 0.40 0.40 <br /> Skylights <br /> U-factor 0.75 <br /> SHGC 0.35 <br /> NR=No requirement,PF=Projection factor. <br /> a. "N"indicates vertical fenestration oriented within 45 degrees of true north. "SEW" <br /> indicates orientations other than"N." For buildings in the southern hemisphere,reverse <br /> south and north. <br /> b. Exception: Jalousie windows are exempt from SHGC requirements." <br /> (12) A new subsection C402.4.3.5 is added to the International Energy Conservation Code <br /> to read as follows: <br /> "C402.4.3.5 Area-weighted SHGC. In commercial buildings, an area-weighted <br /> average of fenestration products shall be permitted to satisfy SHGC requirements. <br /> Exception: Jalousie windows are exempt from SHGC requirements." <br /> (13) Subsection C402.5 of the International Energy Conservation Code is amended to read <br /> as follows: <br /> "C402.5 Air leakage-thermal envelope (Mandatory). The thermal envelope of <br /> buildings shall comply with Sections C402.5.1 through C402.5.8, or the building <br /> thermal envelope shall be tested in accordance with ASTM E 779 at a pressure <br /> differential of 0.3 inch water gauge (75 Pa) [or an equivalent method approved by the <br /> code official] and deemed to comply with the provisions of this section when the <br /> tested air leakage rate of the building thermal envelope is not greater than 0.40 cfm/ft2 <br /> (0.2 L/s • m2). Where compliance is based on such testing, the building shall also <br /> comply with Sections C402.5.5, C402.5.6 and C402.5.7." <br /> (14) A new subsection C403.2.4.2.4 is added to the International Energy Conservation <br /> Code to read as follows: <br /> "C403.2.4.2.4 Door switches. Opaque and glass doors opening to the outdoors in <br /> hotel and motel sleeping units, guest suites, and time-share condominiums, shall be <br /> provided with controls that disable the mechanical cooling or reset the cooling <br /> 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.