My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2020-010 2018-2020
ClerkCouncil
>
Council Records
>
Ordinances
>
2020
>
ORD 2020-010 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 1:36:10 PM
Creation date
2/5/2020 1:34:55 PM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2018-2020
Year
2020
Ordinance
010
Effective Date
2/4/2020
Document Relationships
BIL 126 Draft 01 2018-2020
(Related)
Path:
\Council Records\Bills\2018-2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Exception: A water heating device as approved via Solar Hot Water Heater <br /> Variance by the Department of Business, Economic Development& Tourism, <br /> Hawai'i State Energy Office." <br /> (39) A new subsection R404.2 is added to the International Energy Conservation Code to <br /> read as follows: <br /> "R404.2 Ceiling Fans. A ceiling fan, ceiling fan rough-in, or whole house fan may <br /> be provided for bedrooms and the largest habitable space that is not used as a <br /> bedroom." <br /> (40) A new subsection R404.3 is added to the International Energy Conservation Code to <br /> read as follows: <br /> "R404.3 Electrical vehicle charger power. An electrical rough-in of a 30 amp <br /> circuit for future electrical vehicle charger may be installed in garage/carport area." <br /> (41) TABLE 405.5.2(1) of the International Energy Conservation Code is amended to read <br /> as follows: <br /> "TABLE R405.5.2(1) <br /> SPECIFICATIONS FOR THE STANDARD REFERENCE AND <br /> PROPOSED DESIGNS <br /> BUILDING STANDARD REFERENCE DESIGN PROPOSED <br /> COMPONENT DESIGN <br /> Type: mass wall if proposed wall is mass; otherwise As proposed <br /> wood frame <br /> Above-grade walls Gross area: same as proposed As proposed <br /> U-factor: as specified in Table R402.1.4 As proposed <br /> Solar absorptance=0.75 As proposed <br /> Emittance= 0.90 As proposed <br /> Type: same as proposed As proposed <br /> Basement and crawl Gross area: same as proposed As proposed <br /> space walls U-factor: from Table R402.1.4,with insulation layer on As proposed <br /> interior side of walls <br /> Type: wood frame As proposed <br /> Above-grade floors Gross area: same as proposed As proposed <br /> U-factor: as specified in Table R402.1.4 As proposed <br /> Type: wood frame As proposed <br /> Ceilings Gross area: same as proposed As proposed <br /> U-factor: as specified in Table R402.1.4 As proposed <br /> 21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.