Laserfiche WebLink
DPW/LRB <br /> CONSTRUCTION CODE - DRAFT 5/26/20 <br /> For review and comment <br /> (7) Structures in high seismic zones. (Category E or Sv> 0.75) <br /> (d) All plans and specifications for retaining walls over four feet in height shall be prepared, <br /> designed, and stamped by a person who is licensed in the State of Hawaii as an architect or <br /> professional civil or structural engineer. 15-25(d).} <br /> (e) Electrical plans and specifications giving such details of the proposed installation as may <br /> be required by the authority having jurisdiction to be submitted with the application. Such <br /> plans and specifications shall be prepared, designed, and stamped by a person who is <br /> licensed in the State of Hawaii as aprofessional electrical engineer. <br /> Exception: <br /> For single and two-family dwellings, townhouses and accessory structures, plans and <br /> specifications shall not be required provided the installation meets all of the following <br /> criteria: <br /> (A) The installation shall not be located in a rain water or sea water flood zone; and <br /> (B) Service size disconnect does not exceed 200 amperes. {9-33(a).) <br /> (f) Installation of photovoltaic systems shall require: <br /> (1) Electrical design drawings and specifications that have been prepared, designed, and <br /> stamped by a person who is licensed in the State of Hawaii as a professional <br /> electrical engineer for residential and non-residential installations; and {9-33(b)(2).) <br /> (2) Plans and specifications for building work that have been prepared, designed, and <br /> stamped by a person who is licensed in the State of Hawaii as an architect or a <br /> professional structural engineer for: <br /> (A) Non-residential installations; or {9-33(b)(3).) <br /> (B) Residential installations that do not utilize a preapproved system or that are not <br /> consistent with approved standards including but not limited to, those relating to <br /> span tables, older homes or site-built trusses. <br /> (g) Installation of electrical work on residential and nonresidential electrical work in special <br /> flood hazard areas shall be prepared, designed, and stamped by a person who is licensed in <br /> the State of Hawaii as a professional electrical engineer. <br /> (h) Mechanical plans, included but not limited to plumbing installation and HVAC installation <br /> drawings, specifications shall be prepared, designed, and stamped by a person who is <br /> licensed in the State of Hawaii as a professional engineer, and shall be according to State <br /> statutes when required by the authority having jurisdiction. Plans for single- or two family <br /> dwellings are not required to show plumbing piping plans or diagrams unless requested by <br /> the authority having jurisdiction. <br /> (i) Plumbing plans and diagrams shall be required for R-3 single and two family dwellings and <br /> townhouses that include four or more bathrooms; <br /> 21 <br />