My WebLink
|
Help
|
About
|
Sign Out
Home
Chapter 05E Energy Conservation Code
PublicDocuments
>
County Clerk - Council
>
County Clerk
>
County Code
>
Chapter 05E Energy Conservation Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2022 9:11:08 AM
Creation date
4/9/2021 8:04:49 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
§ 5E-2-1 H AWAI‘I C OUNTY C ODE <br />Type: wood frameAs proposed <br />Above-grade floorsGross area: same as proposedAs proposed <br />U-factor: as specified in Table R402.1.4 As proposed <br />Type: wood frameAs proposed <br />Ceilings Gross area: same as proposed As proposed <br />U-factor: as specified in Table R402.1.4As proposed <br />Type: composition shingle on wood <br />As proposed <br />sheathing <br />Gross area: same as proposed As proposed <br />Roofs <br />Solar absorptance = 0.75 As proposed <br />Emittance= 0.90As proposed <br />2 <br />Type: vented with aperture = 1 ft per <br />i <br />AtticsAs proposed <br />2 <br />300 ft ceiling area <br />Type: same as proposed As proposed <br />Foundation wall area above and below <br />Foundations <br />grade and soil characteristics: same as As proposed <br />proposed <br />2 <br />Area:40 ft As proposed <br />Orientation: NorthAs proposed <br />Opaque doors <br />U-factor: same as fenestration from Table <br />As proposed <br />R402.1.4 <br />h <br />Total area= <br />(a) The proposed glazing area, where the <br />proposed glazing area is less than 15 <br />percent of the conditioned floor area <br />As proposed <br />(b) 15 percent of the conditioned floor <br />area, where the proposed glazing area <br />is 15 percent or more of the <br />conditioned floor area <br />Orientation: equally distributed to four <br />Vertical fenestration <br />cardinal compass orientations (N, E, S & As proposed <br />other than opaque <br />W). <br />doors <br />U-factor: as specified in Table R402.1.4As proposed <br />SHGC: as specified in Table R402.1.2 <br />except that for climates with no <br />As proposed <br />requirement (NR) SHGC = 0.40 shall be <br />used. <br />Interior shade fraction: 0.92 - (0.21 × 0.92 -(0.21 × SHGC as <br />SHGC for the standard reference design) proposed) <br />External shading: noneAs proposed <br />Skylights None As proposed <br />SUPP. 9 (1-2021) <br /> <br />5E-22 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.