Laserfiche WebLink
Shipman Road to the property via two side by side 25-foot wide road and utility <br /> easements located via the flagpole portions of TMK's: 1-6-141:001 and 024 and continue <br /> over TMK's: 1-6-141:027 and 028. In 2017,the Department of Public Works did not <br /> recommend improvements because access to the property is over private lots with utility <br /> and roadway easements. However, due to several of the industrial rezonings previously <br /> approved along Milo Street a condition of approval in Change of Zone Ordinance No. 17 <br /> 65 required the applicant to comply with the standards outlined in the Standard Details R- <br /> 33 and R-34 for Public Works Construction prior to issuance of a Certificate of <br /> Occupancy. Standard Detail R-33 identifies the street cross section for business and <br /> industrial standards,which is a 60-foot wide right of way with 12-foot wide paved travel <br /> lanes, 8-foot wide paved shoulders and 10-foot wide paved drainage swales. The <br /> applicant has proposed to amend Condition I`s timing trigger for roadway improvements <br /> to be Subdivision Approval rather than Certificate of Occupancy. <br /> The Planning Director believes that the timing trigger for this condition should be <br /> Certificate of Occupancy, for any new structures excluding structures that do not require <br /> a certificate of occupancy. Thus, a storage building and utility shed would not trigger it; <br /> however a new beverage facility would trigger that improvement for the subject parcel's <br /> road and utility easement access. Futhermore, if and when the property is subdivided <br /> and/or a condominium property regime (CPR)has occurred,the road improvement <br /> requirements of the Subdivision Code would be triggered,which would provide <br /> improved shoulders, drainage swales, etc. Lastly, the Planning Director is proposing to <br /> remove the Standard Details for Public Works Construction,which is specific and may <br /> change if changes are made to DPW's Standard Details or the Subdivision Code and <br /> replace it with the following to be added to Condition I"with the requirements of Chapter <br /> 23, Hawaii County Code (Subdivision)." <br /> DWS system standards require that a minimum flow of 2,000-gallons per minute <br /> for a 2-hour duration and a pipeline velocity of less than 10-feet per second be available <br /> at the site for fire protection for industrial land uses. The existing 4-inch waterline <br /> fronting the property is inadequate for fire protection and the nearest fire hydrant is more <br /> than the required 150 feet from the property. Based on the preceding, a condition of <br /> -4- <br />