Laserfiche WebLink
County of Hawaii, Planning Dept. Section E <br />PL.4) Community Planning (Community/Regional Plans, General Plan, Climate Adaptation) Fiscal Year 2023-2024 <br />d. <br />(1) TITLE AND LOCATION (Cityand State) <br />(2) YEAR COMPLETED <br />Risk and Resiliency Assessment and Emergency Response Update, <br />PROFESSIONAL SERVICES <br />CONSTRUCTION (if applicable) <br />Hilo, Hawaii <br />2022 <br />N/A <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE ❑x Check if project performed with current firm <br />Project Oversight. BC performed a risk and resiliency assessment that included an evaluation of County of Hawaii, <br />Department of Water Supply (HDWS) seven largest systems that met the threshold for America's Water Infrastructure <br />Act 2018 compliance requirements. BC developed a custom vulnerability assessment tool that evaluated HDWS's <br />critical assets against the selected natural hazards and malevolent acts. The tool produced a prioritized risk score <br />for each asset based on the identified threat and the results will be used to support HDWS's future improvement <br />planning. BC also updated HDWS's Emergency Response Plan which included updates to the Action Plans to prepare <br />for, respond to, and recover from an emergency event. <br />Total Contract Amount: $535K Client: County of Hawaii, Dept. of Water Supply <br />e. <br />(1) TITLE AND LOCATION (Cityand State) <br />(2) YEAR COMPLETED <br />DWS Power System Studies, Hawaii Island, Hawaii <br />PROFESSIONAL SERVICES <br />CONSTRUCTION (if applicable) <br />2020 <br />N/A <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE ❑x Check if project performed with current firm <br />Project Oversight/Client Manager. BC performed power system studies for 33 facilities representing approximately <br />one-third of the Department of Water Supply's source well and distribution facilities. Modeled and analyzed electrical <br />distribution systems to evaluate existing equipment ratings, protective device coordination, and arc flash hazard. <br />Resulted in development and application of arc flash hazard labels complying with NFPA 70E, Standard for Electrical <br />Safety in the Workplace, improving operator safety by warning of the degree of arc flash hazard present and dictating <br />personal protective equipment requirements. Coordinated and supervised an electrical subcontractor to perform <br />National Electrical Testing Association testing on circuit breakers to determine if existing circuit breakers were in <br />adequate and operable condition. Performed electrical and mechanical assessments to analyze well pump failures <br />and provided recommendations for well improvements and operational changes to reduce frequency of these failures. <br />Total Contract Amount: $1.1M Client: County of Hawaii, Dept. of Water Supply <br />BrownANoCaldwell I STANDARD FORM 330 (REV. 6/2006) : 8 <br />