Laserfiche WebLink
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT -C <br />(Complete one Section E for each key person.) cwwanit <br />12. NAME 13. ROLE IN THIS CONTRACT 14. YEARS EXPERIENCE <br />Jordan Moniuszko, PE CCM Environmental/Civil Engineer, a. TOTAL b. WITH CURRENT FIRM <br />Construction Manager 14 9 <br />15. FIRM NAME AND LOCATION (City and State) <br />Oceanit Laboratories, Inc, Honolulu, Hawai'i <br />16. EDUCATION (Degree and Specialization) 17. CURRENT PROFESSIONAL REGISTRATION (State and Discipline) <br />B.S. / 2009 / Mechanical Engineering Hawaii / Civil Engineering / 2018 <br />B.S. / 2009 / Environmental Science <br />18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.) <br />2009 / SCUBA Open Water; 2009 / Environmental Compliance Training and Tracking System; 2010 / OSHA 30 Hour Construction <br />Safety & Health; 2010 / National Pollutant Discharge Elimination System Awareness; 2013 / CPR & First Aid; 2013 / OSHA 24 Hour <br />Confined Space Competent Person; 2014 / Hawaii DOBOR Safe Boating; 2021 / OSHA 2 Hour Asbestos Awareness <br />19. RELEVANT PROJECTS <br />(1) TITLE AND LOCATION (City and State) <br />2 YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />Ongoing <br />CONSTRUCTION (If applicable) <br />2024 (Est.) <br />Waikiki Aquarium Effluent Disposal System Upgrade <br />Honolulu, Hawai'i <br />a. <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE M Check if project performed with current firm <br />Project Manager for this project to evaluate, permit, and design upgrades to the aquatic life exhibit effluent disposal system in <br />order to meet updated NPDES regulatory requirements. The team consisted of civil, electrical, and mechanical engineers, <br />biologist, hydrogeologist, and aquatic life support system specialist. <br />(1) TITLE AND LOCATION (City and State) <br />2 YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />Ongoing <br />CONSTRUCTION (If applicable) <br />2022 (Est.) <br />Anahola Farm Lots Subdivision Water System Improvements <br />Anahola, Hawai'i <br />b. <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE M Check if project performed with current firm <br />Project Engineer for this project to replace a rural subdivision 0.5 MG water tank, water transmission lines and appurtenances, <br />and install a system interconnection with County water system. The team consisted of civil, structural, mechanical, and <br />electrical engineers. <br />(1) TITLE AND LOCATION (City and State) <br />2 YEAR COMPLETED <br />IAB Basement Water Infiltration Repairs at Daniel K Inouye Intl Airport <br />Honolulu, Hawai'i <br />PROFESSIONAL SERVICES <br />Ongoing <br />CONSTRUCTION (If applicable) <br />2023 (Est.) <br />C. <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE M Check if project performed with current firm <br />Project Engineer for this project to investigate sources of and design repairs for flooding to the basement of the overseas <br />terminal at Honolulu International Airport. A variety of techniques were used to scan concrete and gather data to confirm <br />sources of water infiltration. Final design includes repairs to floor slab, exterior and interior drainage improvements, and new <br />floor slab installation. <br />(1) TITLE AND LOCATION (City and State) <br />2 YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />2021 <br />CONSTRUCTION (If applicable) <br />2022 <br />Salt Lake Watershed Structural BMP Implementation <br />Salt Lake, Hawai'i <br />d. <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE M Check if project performed with current firm <br />Project Engineer for this project to install remote sensors and stormwater samplers, collect water quality and meteorologic data, <br />develop and calibrate a watershed model, model various BMP scenarios, design various structural stormwater Best <br />Management Practice measures, and provide construction management services at Salt Lake Watershed in urban Honolulu. <br />(1) TITLE AND LOCATION (City and State) <br />2 YEAR COMPLETED <br />Ka'elepulu Pond & Wetland Environmental Maintenance Dredging <br />Kailua, Hawai'i <br />PROFESSIONAL SERVICES <br />Ongoing <br />CONSTRUCTION (If applicable) <br />2022 (Est.) <br />e. <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE M Check if project performed with current firm <br />Design Engineer and Construction Manager for an ecosystem restoration project to reconnect two estuarine bodies of water <br />located in Windward Oahu. Federal, State and local permits and implementation of associated regulatory conditions were <br />required prior to construction. <br />(1) TITLE AND LOCATION (City and State) <br />2 YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />2016 <br />CONSTRUCTION (If applicable) <br />Kahalu'u Flood Control Lagoon Maintenance Dredging Kaneohe, Hawai'i <br />for Department of Design and Construction <br />f. <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE M Check if project performed with current firm <br />Project Engineer for this windward Oahu maintenance dredging and upland disposal project currently in progress for the City <br />and County of Honolulu. Wrote and executed Sediment Sampling and Analysis Plan. Performed upland disposal scenario and <br />cost estimate analysis. To perform design and services during bidding. <br />(1) TITLE AND LOCATION (City and State) <br />2 YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />CONSTRUCTION (If applicable) <br />Kawainui Stream Flow Restoration Kailua, Hawai'i for <br />Department of Land and Natural Resources <br />2015 <br />2015 <br />g' <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE M Check if project performed with current firm <br />Project Engineer for this environmental remediation project. Designed and installed a temporary levee overflow siphon to return <br />flow to the Kawainui Stream and Hamakua Marsh from the Kawainui Marsh in an experimental study. Gathered water quality <br />data from before and after the temporary siphon installation. Preliminary design of a permanent siphon constructed through the <br />levee. <br />STANDARD FORM 330 (REV. 7/2021) <br />