(45) Amending Section 608.3. Section 608.3 is amended by deleting the following third <br />paragraph: <br />"In addition to the required pressure or combination pressure and <br />temperature relief valve, an approved, listed expansion tank or <br />other device designed for intermittent operation for thermal <br />expansion control shall be installed whenever the building supply <br />pressure is greater than the required relief valve pressure setting or <br />when any device is installed that prevents pressure relief through <br />the building supply. The tank or device shall be sized in <br />accordance with the manufacturer's recommendation." <br />(46) Amending Section 609.1. Section 609.1 is amended by deleting the last two <br />sentences of the section and adding at the end a paragraph to read: <br />"The minimum cover shall be six (6) inches below finish grade or <br />as approved by the administrative authority." <br />(47) Amending Section 609.2. Section 609.2 is amended by changing "as" to "with" in <br />the first line. <br />(48) Amending Section 609.3.2. Section 609.3.2 is amended by adding at the end of the <br />first sentence "or soldered with 95 -5 Tin Antimony solder." <br />(49) Amending Section 609.7.2. Section 609.7.2 is amended by changing the last two <br />sentences to read: <br />"Such an agreement shall be as a part of the conditions of <br />ownership of said properties and shall be binding on all heirs, <br />successors and assigns to such properties." <br />(50) Amending Table 6 -4 Water Supply Fixture Units (WSFU) and Minimum Fixture <br />Branch Pipe Sizes. Table 6 -4 is amended as follows: <br />A) Deleted the figures under "3 or more Dwellings" and "Heavy - <br />Use Assembly." <br />B) Changed the values ( "Minimum Fixture Outlet Pipe Size" and <br />"Notes" remain unchanged) for the following fixtures: <br />- Bathtub or Combination Bath/Shower; <br />Clotheswasher, domestic; <br />Kitchen Sink, domestic; <br />Lavatory; <br />Shower; <br />Urinal, 1.0 GPF; <br />Water Closet, 1.6 GPF Gravity Tank; <br />24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.