Keaau Fire Station Supplemental Hazardous Materials Survey
PublicDocuments
>
Public Works
>
Building Division
>
Keaau Fire Station Supplemental Hazardous Materials Survey
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/13/2018 11:10:42 AM
Creation date
10/24/2017 8:51:02 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2.0EXECUTIVE SUMMARY <br />Lehua Environmental Inc. (LEI) has completed this supplemental hazardous materials survey for the <br />County of Hawaii Keaau Fire Station located at 16-579 Old Volcano Road in Keaau, Hawaii (Subject <br />Site). This report supplements the Previous Report conducted by EKNA Service, Inc. On September <br />22, 2017, LEI personnel performed site reconnaissance to identify and inventory suspect asbestos- <br />containing material (ACM), lead painted surfaces, mercury-containing lamps and PCB-containing light <br />ballasts not previously identified at the Subject Site. <br />Summary of ACM Survey <br />The 1” x 1” ceramic floor tiles and associated grout and leveling compound were identified to be non- <br />ACM by laboratory analysis. No ACM was identified during this supplemental hazardous materials <br />survey at the Subject Site. <br />Table 1 located in Appendix I summarizes this result. <br />Summary of Lead Paint Survey <br />One (1) sampled painted surface was identified to have a lead paint concentration greater than or equal <br />to 5,000 mg/kgand is considered to be Lead-Based Paint (LBP). The LBP was identified was the beige <br />metal conduit pipe located in Room 108 of the Subject Site. The following table lists this result. <br />Table 2 located in Appendix I summarizes the results of all the samples collected during the lead paint <br />survey. <br />Identified Lead Paint <br />Supplemental Hazardous Materials Survey <br />Keaau Fire Station <br />Interior/ <br />Floor Location Description Color Substrate Cond. LCP or LBP? <br />Exterior <br />1 Room 108 Conduit pipe Beige Metal Interior Good LBP <br />Supplemental Hazardous Materials Survey October 23, 2017 <br />Keaau Fire Station <br />2 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.