2007 SUPPLEMENT TO THE IRC <br />Exceptions: <br />1. Blocking at horizontal joints shall not be required in wall segments that are not counted as braced wall <br />panels. <br />2. Where the bracing percentage provided is at least twice the minimum percentage required by Table <br />R602.10.1(1) blocking at horizontal joints shall not be required in braced wall panels constructed using <br />Methods 3, 4, 5, 6, or 8. <br />R602.10.8 Cripple wall bracing. In Seismic Design Categories other than D2, cripple walls shall be braced with <br />a percentage and type of bracing as required for the wall above in accordance with Table R602.10.1(1) with the <br />following modifications for cripple wall bracing: <br />1. The percentage of bracing as determined from Table R602.10.1(1) shall be multiplied by a factor of 1.15, <br />and <br />2. The wall panel spacing shall be decreased to 18 feet (5486 mm) instead of 25 feet (7620 mm). <br />R602.10.8.1 Cripple wall bracing in Seismic Design Categories Do, D1 and D2. In addition to the requirements <br />of Section R602.10.8, where interior braced wall lines occur without a continuous foundation below, the length of <br />parallel exterior cripple wall bracing shall be one and one-half times the length required by Table R602.10.1(1). <br />Where cripple walls braced using Method 3 of Section R602.10.2 cannot provide this additional length, the <br />capacity of the sheathing shall be increased by reducing the spacing of fasteners along the perimeter of each <br />piece of sheathing to 4 inches (102 mm) on center. <br />In Seismic Design Category D2, cripple walls shall be braced in accordance with Table R602.10.1(1). <br />R602.10.8.2 Redesignation of cripple walls. In any Seismic Design Category, cripple walls shall be permitted <br />to be redesignated as the first story walls for purposes of determining wall bracing requirements. If the cripple <br />walls are redesignated, the stories above the redesignated story shall be counted as the second and third stories <br />respectively. <br />R602.11 Wall anchorage. Braced wall line sills shall be anchored to concrete or masonry foundations in <br />accordance with Sections R403.1.6 and R602.11.1 <br />602.11.1 Wall anchorage for all buildings in Seismic Design Categories Do, D1 and D2 and townhouses in <br />Seismic Design Category C. Plate washers, a minimum of 0 22 inch by 3 inches by 3 inches (5.8 mm by 76 <br />mm by 76 mm) in size, shall be provided between the foundation sill plate and the nut except where approved <br />anchor straps are used. The hole in the plate washer is permitted to be diagonally slotted with a width of up to <br />3/16 inch (5 mm) larger than the bolt diameter and a slot length not to exceed 1-3/4 inches (44 mm), provided a <br />standard cut washer is placed between the plate washer and the nut, <br />R602.11.2 Stepped foundations in Seismic Design Categories Do, D1 and D2. In all buildings located in <br />Seismic Design Categories Do, D1 or D2, where the height of a required braced wall line that extends from <br />foundation to floor above varies more than 4 feet (1220 mm), the braced wall line shall be constructed in <br />accordance with the following: <br />1. Where the lowest floor framing rests directly on a sill bolted to a foundation not less than 8 feet (2440 mm) <br />in length along a line of bracing, the line shall be considered as braced The double plate of the cripple stud <br />wall beyond the segment of footing that extends to the lowest framed floor shall be spliced by extending the <br />upper top plate a minimum of 4 feet (1219 mm) along the foundation. Anchor bolts shall be located a <br />maximum of 1 foot and 3 feet (305 and 914 mm) from the step in the foundation.. See Figure R602.11.3. <br />2. Where cripple walls occur between the top of the foundation and the lowest floor framing, the bracing <br />requirements of Sections R602.10 8 and R602,10.8.1 shall apply. <br />3. Where only the bottom of the foundation is stepped and the lowest floor framing rests directly on a sill <br />bolted to the foundations, the requirements of Sections R403,1.6 and R602,11.1 shall apply.. <br />Section R606.3 Change to read as shown: (RB238-06/07) <br />R606.3 Corbeled masonry. Corbeled masonry shall be in accordance with Sections R606.3.1 through R606.3.3. <br />Section R606.3.1, R606.3.2, R606.3.3 Add new sections to read as shown: (RB238-06/07) <br />R606.3.1 Units. Solid masonry units or masonry units filled with mortar or grout shall be used for corbeling. <br />IRC -54 <br />ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION ISA VIOLATION OE THE II"4 DERAL COPYRIGHT ACT No lTHI TENSE AGR aEMEN T AND SUBJECT aTO CIVIL, <br />copyrighted 02007 ICC ALL RIGHTS RESERVED),licensed to Neil Erickson pursuant to License Agreement with ICC <br />AND THu•, LICENSE AGREEMENT, Ca�UB.VEif:;P" TV°.A CIVIL AND CRIMINAL PENALTIES THEREUNDER, <br />
The URL can be used to link to this page
Your browser does not support the video tag.