2007 SUPPLEMENT TO THE IRC <br />R606.3.2 Corbel projection. The maximum projection of one unit shall not exceed one-half the height of the unit <br />or one-third the thickness at right angles to the wall. The maximum corbeled projection beyond the face of the wall <br />shall not exceed: <br />1. One-half of the wall thickness for multiwythe walls bonded by mortar or grout and wall ties or masonry <br />headers, or <br />2. One-half the wythe thickness for single wythe walls, masonry -bonded hollow walls, multiwythe walls with <br />open collar joints and veneer walls. <br />R606.3.3 Corbeled masonry supporting floor or roof -framing members. When corbeled masonry is used to <br />support floor or roof -framing members, the top course of the corbel shall be a header course or the top course <br />bed joint shall have ties to the vertical wall. <br />Section R606.4.2 Change to read as shown: (R13238-06/07) <br />R606.4.2 Support at foundation. Cavity wall or masonry veneer construction may be supported on an 8 -inch <br />(203 mm) foundation wall, provided the 8 -inch (203 mm) wall is corbeled with solid masonry to the width of the <br />wall system above. The total horizontal projection of the corbel shall not exceed 2 inches (51 mm) with individual <br />corbels projecting not more than one-third the thickness of the unit or one-half the height of the unit. The hollow <br />space behind the corbeled masonry shall be filled with mortar or grout. <br />Section R606.12.2.1, Table R606.12.2.1 Add new section and table to read as shown: (RB239-06/07) <br />R606.12.2.1 Minimum length of wall without openings. Table R606.12.2.1 shall be used to determine the <br />minimum required solid wall length without openings at each masonry exterior wall. The provided percentage of <br />solid wall length shall only include those wall segments that are 3 feet (914 mm) or longer. The maximum clear <br />distance between wall segments included in determining the solid wall length shall not exceed 18 feet (5486 mm). <br />Shear wall segments required to meet the minimum wall length shall be in accordance with Section <br />R606.12.2.2.3. <br />TABLE R606.12.2.1 <br />MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES <br />MINIMUM SOLID WALL LENGTH (percent) <br />Wall Supporting Light- Wall Supporting <br />Story of Two Story Framed Second Story Masonry Second Story <br />and Roof and Roof <br />35 <br />Seismic Design Category <br />One Story or Top <br />Townhouses in C 20 <br />Do or D <br />25 <br />25 NP NP <br />D��-mro,��rvrv, �„��, 30 ,� NP <br />NP = Not permitted, expect with design in accordance with the International Building Code. <br />a, For all walls, the minimum required length of solid wails shall be based on the table percent multiplied by the <br />dimension, parallel to the wall direction under consideration, of a rectangle inscribing the overall building plan. <br />NP <br />Section R607.2.1.1 Change to read as shown: (RB240-06/07) <br />R607.2.1.1 Mortar joint thickness tolerance. Mortar joint thickness for load bearing masonry shall be within the <br />following tolerances from the specified dimensions <br />1. Bed joint: + 1/8 inch (3 mm). <br />2. Head joint: -1/4 inch (7 mm), + 3/8 inch (10 mm). <br />3. Collar joints: -114 inch (7 mm), + 3/8 inch (10 mm). <br />Sections R613, R613.1 Change to read as shown: (RB244-06/07) <br />SECTION R613 <br />EXTERIOR WINDOWS AND DOORS <br />R613.1 General. This section prescribes performance and construction requirements for exterior window and <br />door systems installed in wall systems, Windows and doors shall be installed and flashed in accordance with the <br />fenestration manufacturer's written installation instructions. Window and door openings shall be flashed in <br />accordance with Section R703.8. Written installation instructions shall be provided by the fenestration <br />manufacturer for each window or door. <br />IRC -55 <br />Coppnontoo c 2007 ICC (ALL RIGHTS RESE'RVEDy. Iicensao NJ Neil Erickson pursuant to License Awn:arcoerol with ICC No further rep ' +ructioroo at hca*/ u r or rlisInbutiorr authorized. <br />ANY UNAUTHROr7ED REPRODUCTION OR DISTRIBUTION IS A VI0LATOON OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT, AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER <br />
The URL can be used to link to this page
Your browser does not support the video tag.