Laserfiche WebLink
i <br /> subdivision sewer system installed in other than publicly owned property. The subdivider <br /> shall also convey to the County fee simple title to all sites on which a pumping station or <br /> treatment plant is constructed by the subdivider as part of the public sewage works, <br /> together with easements for ingress and egress. <br /> (b) Final approval and acceptance of subdivision sewage works shall not be granted until the <br /> subdivider has settled all financial accounts with the County. <br /> Division 3. Laterals. <br /> Section [21 20.]21-04-31. Application. <br /> An application for a lateral to a lot shall be made on a form prescribed [f rm to the b,,,.ea <br /> of e=wef s.] b t�partment and submitted to the director. If the lateral has not already been <br /> run to the property line, the County will construct it as soon as possible at the expense of the <br /> applicant, except as provided by section [21-14.] 21-04-04. <br /> Section [21 21.]21-04-32. Location. <br /> New laterals shall be installed as near as practicable to the exact location desired by the <br /> applicant, but if branches are already in the main or other outlets are available near at hand, the <br /> lateral may be run from them. The County reserves the right to establish the alignment of the <br /> lateral, the location of the connection and to provide service to other lots from the same lateral. <br /> Section [21 22121-04-33. Construction specifications. <br /> (a) All laterals shall be six inches in diameter and constructed at right angles to the main on a <br /> minimum grade of[ .] one <br /> percent. Each lateral shall terminate at the property line with a [six inch by F of inch ea <br /> int] six inch by four inch pipe reducer, properly capped. <br /> (b) Connection of the [bail ing sewef] property lateral to this reducer and cleanout shall be <br /> [made] completed with a forty-five degree [east n] "Y," with the branch facing upward <br /> and extended [abetrt] one inch above the ground with a [four-inch] counter sunk six inch <br /> brass plug cleanout at the end. The exception is a sidewalk and driveway area where the <br /> cast iron cleanout box and cover shall be flush with the surface. The counter sunk six inch <br /> brass plug within the box shall be at a minimum of one-half inch below the cover. This <br /> connection shall not be backfilled or covered until approved by the director. <br /> Section [213:]21-04-34. Deposit required; inadequate deposit; refunds. <br /> A deposit [Afnot Tor than $25 and at yeast] equal to the County's estimate of the cost of the <br /> lateral shall be required of the applicant before the lateral is installed. If the actual cost of the <br /> lateral is in excess of the deposit, the applicant will be billed and shall pay for the difference. If <br /> the actual cost is less than the deposit, the applicant shall be refunded the difference. <br /> Section [2-1--24:]21-04-35. Charge for pre-existing lateral. <br /> No new charge shall be made for a lateral which has already been installed to the property <br /> line of the lot, the charge for which has already been paid. <br /> 10 <br /> 'i <br /> i <br />