My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 025 Draft 01 1996-1998
ClerkCouncil
>
Council Records
>
Bills
>
1996-1998
>
BIL 025 Draft 01 1996-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2010 3:39:12 PM
Creation date
5/10/2008 8:22:29 PM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
1996-1998
Bill/Resolution
025
Draft
01
Introducer
Dominic Yagong, Councilmember Chair, Public Works and Parks Committee
Referred To
PWPC
Action 1
PWPC-10:- Recommends Bill 25 pass first reading - 01/21/97 (PWPC 0012)
Action 2
Council: Amends Bill 25 to Draft 2, as circulated - 02/07/97 (MB 464)
File Code
HCC/BLD
Document Relationships
COM 0075.000 1996-1998
(Related To)
Path:
\Council Records\Communications\1996-1998
REP PWPC 010 01/21/1997 1996-1998
(Related To)
Path:
\Council Records\Reports\1996-1998\Public Works & Parks Committee (PWPC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(B) Exceptions. <br /> (i) Design load calculations need not be submitted for new, individually <br /> permitted cooling systems of ]ess than 65 000 Btu/hr capacity that <br /> provide less than 37 Btu/hr of installed capacityper square foot of <br /> conditioned floor area. <br /> (ii) Design load calculations need not be submitted when existing <br /> cooling equipment is replaced with equipment of equal or less capacity." <br /> SECTION 13. Section 5-29.3.(g) of the Hawaii County Code 1983 (1995 Edition) relating <br /> to Materials and Construction is hereby amended so that Table 9-1 relating to <br /> Minimum Pipe Insulation reads as follows: <br /> Table 9-1 <br /> Minimum Pipe Insulation (Inches). <br /> Insulation Conductivity Nominal Pipe Diameter (inches) <br /> Fluid Design Mean <br /> Operating Temp., Cond. Range, Rating Runouts° 1 and 8 and <br /> Range °F Btu • iNh • ft' • °F Temp.,° up to 2 less 1.25 to 2 2.5 to 4 5 and 6 up <br /> F <br /> Heating Systems (Steam. Steam Condensate, and Hot Water) <br /> Above 350 0.32-0.34 250 1.5 2.5 2.5 3.0 3.5 3.5 <br /> 251-350 0.29-0.31 200 1.5 2.0 2.5 2.5 3.5 3.5 <br /> 201-250 0.27.30 I50 1.0 1.5 1.5 2.0 2.0 3.5 <br /> 141-200 0.25-0.29 125 0.5 1.5 1.5 I.5 I.5 1.5 <br /> 105-140 0.24--0.28 100 0.5 1.0 1.0 1.0 1.5 1.5 <br /> Domestic and Service Hot Watef <br /> 105 and greater 0.24-0.28 100 0.5 1.0 1.0 1.5 1.5 1.5 <br /> Cooling Systems (Chilled Waur, Htine and Refrigerant)° <br /> 40-55 0.23-0.27 75 0.5 0.5 0.75 1.0 1.0 1.0 <br /> Below 40 0.23-0.27 75 1.0 1.0 1.5 1.5 1.5 1.5 <br /> <br /> Noes: <br /> <br /> a. For minimum thicknesses of alternative insulation types, see section 5-2.9.3(8)(2). <br /> <br /> b. Runouts to individual terminal units not exceeding 12 feet in length. <br /> <br /> c. Applies to recirculation sections of service or domestic hot water systems and first 8 feet oP hot warPr ninrnQ from <br /> storage tank for nomecirculating systems. <br /> d. The required minimum thicknesses do not consider water vapor uansmission and condensation. Additional insulation <br /> and/or vapor retarders may be required to limit water vapor [ransmission and condensation. <br /> 13 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.