Laserfiche WebLink
(b) Plans, specifications, engineering calculations, diagrams, soil investigation reports, code search, <br />special inspection and structural observation programs and other data shall constitute the submittal <br />documents and shall be submitted in one or more sets with each application for permit. <br />(c) All plans and specifications relating to work which affects the public safety or health and for which <br />a building permit is required shall be prepared, designed and stamped by a duly registered <br />professional engineer or architect in accordance with chapter 464, Hawai`i Revised Statutes. <br />For residential (R -3 Occupancies) and accessory (U Occupancies) only, plans and specifications <br />shall be designed and stamped by a professional architect or structural engineer when any of the <br />following applies: <br />(1) Single story structure and more than 600 square feet of floor area for R -3 Occupancy. <br />(2) Single story or two -story structure of mixed occupancies (R -3 and U Occupancies) with more <br />than 1,200 square feet of total floor area. Item #1 criteria applies. <br />(3) Structures of R -3 or U Occupancies that are three or more stories in height. <br />(4) Flood Zone. <br />(5) Structural members are concrete, masonry or steel. <br />(d) All plans for retaining walls over 4 feet in height shall be designed and stamped by a professional <br />architect or engineer in the structural or civil branches, pursuant to chapter 464, Hawai`i Revised <br />Statutes. <br />(e) All plans for post and pier type construction with/without perimeter foundation walls of R -3 <br />Occupancies shall be designed and stamped by a professional architect or structural engineer. <br />(f) All U Occupancies greater than 600 square feet shall be designed and stamped by a professional <br />architect or structural engineer. <br />(g) All wood trusses of more than 24' -0" spans shall be designed and stamped by a professional <br />architect or structural engineer. All pre- engineered trusses and metal trusses shall be designed and <br />stamped by a professional architect or structural engineer. <br />(h) The building official may require plans, computations, and specifications to be prepared and <br />designed by an engineer or architect licensed by the State of Hawai`i to practice as such. This <br />requirement may be imposed when prescriptive requirements of the building code are not being <br />adhered to. <br />Section 5 -26. Package homes. <br />In lieu of compliance with those provisions of section 5 -25 pertaining to dwellings, model package <br />homes (homes manufactured in a factory and ready to be assembled on the job site) may be pre- approved <br />as follows by the Hawai`i County Department of Public Works - Building Division (DPW - Building <br />Division). <br />(1) <br />Pre - approval shall be limited to three typical model home designs per manufacturer per year, <br />with no revisions. Any revisions to the pre- approved plans will require submittal of the entire <br />particular revised plans and documents for approval. Minimum square footage shall be 900 <br />square feet and maximum square footage shall be 1,400 square feet living area (not including <br />carport/garage). Maximum 2 -car carport/garage may be included. <br />(2) Pre - approval is good for one (1) calendar year (January to December) for the calendar year in <br />which approval is requested. All model pre- approved shall expire by December 31 of each <br />calendar year. <br />(3) <br />When submitting for pre - approval, applicant shall submit six (6) sets of complete working <br />drawings and specifications along with package home seal and authorizing signature. <br />9 <br />