My WebLink
|
Help
|
About
|
Sign Out
Home
ORD 2017-056 2016-2018
ClerkCouncil
>
Council Records
>
Ordinances
>
2017
>
ORD 2017-056 2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/15/2017 11:42:24 AM
Creation date
8/15/2017 11:41:34 AM
Metadata
Fields
Template:
Ordinances
Ordinances - Type
ORD
Ordinances - Council Term
2016-2018
Year
2017
Ordinance
056
Effective Date
8/14/2017
Document Relationships
BIL 050 Draft 01 2016-2018
(Related)
Path:
\Council Records\Bills\2016-2018
COM 0334.000 2016-2018
(Related To)
Path:
\Council Records\Communications\2016-2018
REP PWPRC 014 2017/07/06 (2016-2018)
(Related To)
Path:
\Council Records\Reports\2016-2018\Public Works & Parks & Recreation Committee (PWPRC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
submitted for approval with the application for the certificate of occupancy.The <br /> information certified within the"Elevation Certificate" shall be based on actual <br /> construction. <br /> (2) Compliance with other requirements of this chapter." <br /> SECTION 10. Chapter 27, article 4, section 27-23, of the Hawai`i County Code <br /> 1983 (2016 Edition, as amended), is amended to read as follows: <br /> "Section 27-23. Standards for coastal high hazard areas. <br /> Coastal high hazard areas[,more commonly known as tsunami inundation areas,] are <br /> identified as Zone V or Zone VE on the Flood Insurance Rate Maps. Within coastal high hazard <br /> areas,the following standards shall apply: <br /> [(-a)](1) All new construction,improvements to repetitive loss structures, and substantial <br /> improvements in a coastal high hazard area shall be constructed with materials <br /> and utility equipment resistant to flood damage and using methods and practices <br /> that minimize flood damage. <br /> [(b)](2) New construction,improvements to repetitive loss structures, and substantial <br /> improvement shall be elevated on adequately anchored pilings or columns and <br /> securely anchored to such pilings or columns so that the lowest horizontal portion <br /> of the structural members of the lowest floor, excluding the pilings and columns, <br /> is elevated to or above the base flood level. The pile or column foundation and <br /> structure attached thereto shall be anchored to resist flotation, collapse, and lateral <br /> movement due to the effects of wind and water loads acting simultaneously on all <br /> building components. The wind and water loading values shall each have a one <br /> percent chance of being equaled or exceeded in any given year. <br /> [(c)](3) New construction, improvements to repetitive loss structures, and other <br /> development shall be located on the landward side of the reach of mean high tide. <br /> [(d)](4) New construction, improvements to repetitive loss structures, and substantial <br /> improvement shall have the enclosed space, if any,below the lowest floor free of <br /> obstructions and constructed with breakaway walls as defined in section 27-12. <br /> Such enclosed space shall not be used for human habitation and will be useable <br /> solely for parking of vehicles,building access,'or storage. Machinery and <br /> equipment which service the building, such as furnaces, air conditioners, heat <br /> pumps,hot water heaters, washers, dryers, elevator lift equipment, electrical <br /> junction and circuit boxes, and food freezers are not permitted in such enclosed <br /> spaces. The enclosed space must only be achieved with breakaway walls, open <br /> wood latticework, or insect screening intended to collapse under wind and water <br /> loads without causing collapse, displacement, or other structural damage to the <br /> elevated portion of the building or supporting foundation system. A breakaway <br /> wall shall have a design safe loading resistance of not less than ten and no more <br /> than twenty pounds per square foot. Use of breakaway walls which exceed a <br /> design safe loading resistance of twenty pounds per square foot may be permitted <br /> only if a licensed professional structural engineer certifies that the design <br /> proposed meets the following conditions: <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.