My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 126 Draft 01 2018-2020
ClerkCouncil
>
Council Records
>
Bills
>
2018-2020
>
BIL 126 Draft 01 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 10:00:45 AM
Creation date
12/2/2019 10:18:15 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2018-2020
Bill/Resolution
126
Draft
01
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
PWMTC
Action 1
Council: Bill 126 passes first reading; adopts PWMTC-20 - 1/8/20
Action 2
Council: Bill 126 passes second & final reading - 1/22/20
Status
Adopted
Date To Mayor or Adoption Date
1/30/2020
Reading Number
1
Reading Date
1/8/2020
Ayes
7-Chung, David, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes
0
Absent
2-Eoff, Kaneali'i-Kleinfelder,
Excused
0
Reading Number .
2
Reading Date .
1/22/2020
Ayes .
7- David, Eoff, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes .
0
Absent .
2-Chung, Kaneali'i-Kleinfelder
Excused .
0
Document Relationships
AGE COUNCIL 2020-01-08 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE COUNCIL 2020-01-22 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE PWMTC 2019/12/17 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Public Works & Mass Transit Committee (PWMTC)
COM 0646.000 2018-2020
(Related)
Path:
\Council Records\Communications\2018-2020
ORD 2020-010 2018-2020
(Related To)
Path:
\Council Records\Ordinances\2020
REP PWMTC 020 2019/12/17 2018-2020
(Related)
Path:
\Council Records\Reports\2018-2020\Public Works & Mass Transit Committee (PWMTC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Lighting equipment that is for sale or for demonstrations in lighting education <br /> shall be controlled by a dedicated control that is independent of the controls <br /> for other lighting within the room or space." <br /> (17) A new subsection C405.10 is added to the International Energy Conservation Code to <br /> read as follows: <br /> "C405.10 Sub-metering (Mandatory). In new buildings with tenants, metering <br /> shall be collected for the entire building and individually for each tenant occupying <br /> 1,000 ft' (total enclosed and unenclosed) (93 in') or more. Tenants shall have access <br /> to data collected for their space. A tenant is defined as "one who rents or leases from <br /> a landlord." <br /> (18) Subsection C406.3 of the International Energy Conservation Code is amended to read <br /> as follows: <br /> "C406.3 Reduced lighting power density. The total interior lighting power(watts) <br /> of the building shall be determined by using [90] 80 percent of the lighting power <br /> values specified in Table C405.4.2(1) times the floor area for the building types, or by <br /> using [90] 80 percent of the interior lighting power allowance calculated by the <br /> Space-by-Space Method in Section 0405.4.2." <br /> (19) Subsection C408.2 of the International Energy Conservation Code is amended to read <br /> as follows: <br /> "C408.2 Mechanical systems and service water-heating systems commissioning <br /> and completion requirements. Pfief to the final meehanieal and plumbing <br /> inspeaians, The registered design professional or approved agency shall provide <br /> evidence of mechanical systems commissioning and completion in accordance with <br /> the provisions of this section to the owner or owner's authorized agent. <br /> Construction document notes shall clearly indicate provisions for commissioning and <br /> completion requirements in accordance with this section and are permitted to refer to <br /> specifications for further requirements. Copies of all documentation shall be given to <br /> the owner or owner's authorized agent and made available to the code official upon <br /> request in accordance with Sections 0408.2.4 and C408.2.5. <br /> Exceptions: The following systems are exempt: <br /> 1. Mechanical systems and service water heater systems in buildings where <br /> the total mechanical equipment capacity is less than 480,000 Btu/h(140.7 <br /> kW) cooling capacity and 600,000 Btulh(175.8 kW) combined service <br /> water-heating and space-heating capacity. <br /> 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.