BIL 126 Draft 01 2018-2020
ClerkCouncil
>
Council Records
>
Bills
>
2018-2020
>
BIL 126 Draft 01 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 10:00:45 AM
Creation date
12/2/2019 10:18:15 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2018-2020
Bill/Resolution
126
Draft
01
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
PWMTC
Action 1
Council: Bill 126 passes first reading; adopts PWMTC-20 - 1/8/20
Action 2
Council: Bill 126 passes second & final reading - 1/22/20
Status
Adopted
Date To Mayor or Adoption Date
1/30/2020
Reading Number
1
Reading Date
1/8/2020
Ayes
7-Chung, David, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes
0
Absent
2-Eoff, Kaneali'i-Kleinfelder,
Excused
0
Reading Number .
2
Reading Date .
1/22/2020
Ayes .
7- David, Eoff, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes .
0
Absent .
2-Chung, Kaneali'i-Kleinfelder
Excused .
0
Document Relationships
AGE COUNCIL 2020-01-08 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE COUNCIL 2020-01-22 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE PWMTC 2019/12/17 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Public Works & Mass Transit Committee (PWMTC)
COM 0646.000 2018-2020
(Related)
Path:
\Council Records\Communications\2018-2020
ORD 2020-010 2018-2020
(Related To)
Path:
\Council Records\Ordinances\2020
REP PWMTC 020 2019/12/17 2018-2020
(Related)
Path:
\Council Records\Reports\2018-2020\Public Works & Mass Transit Committee (PWMTC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
[As pfoposed] <br /> Fuel type: Electric <br /> Cooling systems d,f Efficiency: in accordance with prevailing federal As proposed <br /> minimum standards. <br /> Capacity: sized in accordance with Section 8403.7. As proposed <br /> [As pfepesed] [A-sj�ed] <br /> Fuel type: same as proposed design As propose <br /> Service water heating d, Efficiency: in accordance with prevailing federal As proposed <br /> g minimum standards. <br /> Use: Same as proposed design gal/day=30+ <br /> I <br /> 10x& <br /> Duct insulation: From Section 8403.2.1 <br /> As tested or as <br /> A thermal distribution system efficiency(DSE)of 0.88 specified in Table <br /> Thermal distribution shall be applied to both the heating and cooling system R405.5.2(2)if not <br /> systems efficiencies for all systems other than tested duct tested. Duct <br /> systems. For tested duct systems,the leakage rate shall insulation shall be <br /> be 4 cfm(113.3 L/min)per 100 ft' (9.29 M2) Of as proposed. <br /> conditioned floor area at a pressure of differential of 0.1 <br /> inches w.g (25 Pa). <br /> Thermostat Type: Manual,cooling temperature setpoint=75°F; Same as standard <br /> Heating temperature setpoint=72°F reference <br /> For SL I square foot=0.93 M2, I British thermal unit= 1055 J, I pound per square foot=4.88 kg/ml, <br /> I gallon(US)=3.785 L, 'C=('F-32)/1,8, I degree=0.79 rad. <br /> a. Where required by the code official,testing shall be conducted by an approved party. Hourly calculations <br /> as specified in the ASHRAE Handbook of Fundamentals,or the equivalent shall be used to determine the <br /> energy loads resulting from infiltration. <br /> b. The combined air exchange rate for infiltration and mechanical ventilation shall be determined in <br /> accordance with Equation 43 of 2001 ASHRAE Handbook of Fundamentals,page 26.24 and the"Whole- <br /> house Ventilation"provisions of 2001 ASHRAE Handbook offundamentals,page 26.19 for intermittent <br /> mechanical ventilation. <br /> c. Thermal storage element shall mean a component not part of the floors,walls or ceilings that is part of a <br /> passive solar system,and that provides thermal storage such as enclosed water columns,rock beds,or <br /> phase-change containers.A thermal storage element must be in the same room as fenestration that faces <br /> within 15 degrees(0.26 rad)of true south,or must be connected to such a room with pipes or ducts that <br /> allow the element to be actively charged. <br /> d. For a proposed design with multiple heating,cooling or water heating systems using different fuel types, <br /> the applicable standard reference design system capacities and fuel types shall be weighted in accordance <br /> with their respective loads as calculated by accepted engineering practice for each equipment and fuel type <br /> present. <br /> e. For a proposed design without a proposed heating system,a heating system with the prevailing federal <br /> minimum efficiency shall be assumed for both the standard reference design and proposed design. <br /> f. For a proposed design home without a proposed cooling system, an electric air conditioner with the <br /> prevailing federal minimum efficiency shall be assumed for both the standard reference design and the <br /> proposed design. <br /> g. For a proposed design with a nonstorage-type water heater,a 40-gallon storage-type water beater with the <br /> prevailing federal minimum energy factor for the same fuel as the predominant heating fuel type shall be <br /> assumed. For the case of a proposed design without a proposed water heater, a 40-gallon storage-type <br /> water heater with the prevailing federal minimum efficiency for the same fuel as the predominant heating <br /> fuel type shall be assumed for both the proposed design and standard reference design. <br /> h. For residences with conditioned basements,R-2 and R-4 residences and townhouses,the following formula <br /> shall be used to determine glazing area: <br /> 24 <br />