My WebLink
|
Help
|
About
|
Sign Out
Home
08-08-2022 Applicant's Concurrence to Defer Hearing
PublicDocuments
>
Planning Department
>
Leeward/Windward Planning Commission
>
Board Packets
>
*Background/Recommendation Reports (June 2020-Sept 2022)
>
2022
>
2022-08-18 Leeward
>
Item #1 Kula Nei, LLC (PL-PUD-2022-000002)
>
08-08-2022 Applicant's Concurrence to Defer Hearing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2022 1:21:39 PM
Creation date
8/11/2022 1:21:35 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• Variance#4,Section 25-5-74 . Minimum Building Site Area. Please explain why you <br /> are asking for a 1-acre minimum lot size when the application represents that the <br /> smallest proposed lot is be 2.046 acres? If no specific reason, please change the request <br /> to a minimum of 2 acres. <br /> • Variance#5,Section 25-5-75. Minimum Building Site Average Width.This is another <br /> blanket waiver request, but the application does not propose an alternative number of <br /> feet for the minimum building site average width to accommodate the proposed PUD. If <br /> no alternative width is provided, the final PUD could be created with oddly shaped <br /> lots. Please provide minimum building site average widths based off the proposed <br /> design. <br /> • Variance#6,Section 23-29. Block Sizes. OK with this request. <br /> • Variance#7,Section 23-33. Min Lot Size. Please explain why you are asking for a 1- <br /> acre minimum lot size when the application represents that the smallest proposed lot is <br /> be 2.046 acres? If no specific reason, please change the request to a minimum of 2 <br /> acres. <br /> • Variance#8,Section 23-41. Minimum ROW&Pavement Widths. Is there a specific <br /> design/functional reason for the proposed 'T' cul-de-sac roadway connections from <br /> Road "A"to proposed lots 1 through 4? If so, please provide that specific information. If <br /> not, please consider using flagpole connections with reciprocal easements within the <br /> lots to satisfy the desire of the PUD to reduce roadways. <br /> • Variance#9,Section 23-45. Grades&Curves. Please confirm with the Fire Department <br /> that the proposed roadway curves/turn radii are consistent with Fire Code? If so, please <br /> provide a statement to that effect. <br /> • Variance#10,Section 23-48. Cul-De-Sacs. Please provide a more detailed justification <br /> for this design element.The current justification is just a re-stating of the purpose of a <br /> PUD. Be specific as to why a blanket waiver of this section and the alternative <br /> landscaped cul-de-sac necessary(e.g., is it an aesthetic feature? How does it fit with the <br /> surrounding rural character as stated, etc.)Additionally, it appears that there is direct <br /> roadway connection from the proposed cul-de-sac to proposed lots 5,7 &8, but no <br /> discussion of how lot 6 will be accessed. Please provide an explanation of why this <br /> individual roadway access rather than a traditional cul-de-sac with frontage along each <br /> lot. Please also confirm with the Fire Department that the proposed cul-de-sac <br /> curves/turn radii are consistent with Fire Code? <br /> • Variances#11413. OK with these requests. <br /> • Variance#14. Right-of-Way Improvement. Please provide more detailed discussion & <br /> specific examples of how the proposed ROW improvements are in keeping with the <br /> surrounding, "rural" roadway designs that you represent. <br /> 3. Finally, the application did not include sufficient discussion on how the proposed project meets <br /> the criteria for granting a PUD permit articulated in Section 25-6-10 of the Hawaii County Code. <br /> Sections of those criteria applicable to your project are outlined below: <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.