My WebLink
|
Help
|
About
|
Sign Out
Home
Ordinance 07-084
PublicDocuments
>
County Clerk - Council
>
County Clerk
>
County Code
>
Ordinances
>
Ordinance 07-084
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2011 12:10:16 PM
Creation date
8/30/2011 12:08:12 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
nonpotable water is furnished to a property, the pipes shall be <br />labeled "nonpotable water" above and below ground and at all <br />outlets. Above ground piping shall be labeled at eight -foot <br />maximum intervals. Below ground piping shall be continuously <br />labeled except for irrigation piping." <br />(37) Amending Section 603.4.13. Section 603.4.13 is amended to read: <br />"603.4.13. Potable Water Supply to Carbonators shall be <br />protected by a listed reduced pressure principle backflow preventer <br />or double check valve with intermediate atmospheric vent as <br />approved by the administrative authority for the specific use." <br />(38) Amending Section 603.4.18.1. Section 603.4.18.1 is amended to read: <br />"603.4.18.1. Except as provided under Sections 603.4.18.2 and <br />603.4.18.3 below, potable water supplies to fire protection <br />systems, including but not limited to standpipes and automatic <br />sprinkler systems, shall be protected from back - pressure and back - <br />siphonage by a double check valve assembly or a reduced pressure <br />backflow preventer. <br />EXCEPTIONS: <br />(1) Systems with alarm check valve assembly <br />(2) Systems with detector check assembly <br />(3) One and two family dwellings and mobile homes <br />(4) Systems with booster pumps and check valve assembly. <br />(39) Amending Section 604.1. Section 604.1 is amended to read: <br />"604.1. Water pipe and fittings shall be of brass, copper, cast iron, <br />galvanized steel or other approved materials. Asbestos - cement, <br />CPVC, PB, PE, PEX, PEX -AL -PEX or PVC water pipe <br />manufactured to recognized standards may be used for cold water <br />distribution systems outside a building. CPVC, PB, PEX and <br />PEX -AL -PEX water pipe and tubing may be used for hot and cold <br />water distribution systems within a building. All materials used in <br />the water supply system, except valves and similar devices shall be <br />of a like material, except where otherwise approved by the <br />administrative authority." <br />(40) Amending Section 605.3. Section 605.3 is amended by deleting the last sentence of <br />the paragraph and adding at the end of the paragraph: <br />"EXCEPTION: When a supply riser serves not more than one <br />plumbing fixture in each dwelling unit, the fixture supply stop may <br />22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.