previously have been used for no other purpose than conveying <br />gas; it shall be in good condition and free from internal <br />obstructions. Burred ends shall be reamed to the full bore of the <br />pipe or tubing. <br />1210.4 Fittings, except stopcocks or valves, shall be malleable <br />iron or steel or wrought iron, and shall be copper or brass when <br />used with copper or brass pipe or tubing and shall be aluminum <br />alloy when used with aluminum alloy pipe or tubing. PE fittings, <br />mechanical connectors and transition fittings shall be of the <br />approved types when used with PE piping or tubing. <br />1210.5 Valves: All valves and appurtenances used in connection <br />with the above piping shall be of the type designed and approved <br />for use with fuel gas." <br />(104) Amending Section 1211. 1. Section 1211.1 is amended to read: <br />"1211.1 All pipe joints in the piping system, unless welded, shall <br />be screwed joints, having approved standard threads. Such <br />screwed joints shall be made up with approved pipe joint material, <br />insoluble in the presence of fuel gas and applied to the male <br />threads only. Tubing joints shall either be made with approved <br />flared gas tubing fittings, or be brazed with a material having a <br />melting point in excess of one thousand (1,000) degrees F." <br />(105) Deleting Section 1211.2. <br />Section 1211.2 is deleted. <br />(106) Amending Section 1211.3. Section 1211.3 is amended by amending the Exception <br />note to read: <br />"Exception: When necessary due to structural conditions, <br />approved type gas piping may be installed in other locations when <br />permission has first been obtained from the administrative <br />authority. In non - industrial occupancies, approved machine - <br />wrapped or coated ferrous piping as defined in Section 1211.5 and <br />Section 1211.7 may be encased in an independent concrete jacket <br />with a minimum wall thickness of one and one half (1 -1/2) inches. <br />The protective coating shall extend at least one (1) inch above the <br />point of entry into the slab and above the point of exit from the <br />slab for the appliance riser. Such piping shall not be in physical <br />contact with other metallic objects such as reinforcing rods or <br />electrical neutral conductors." <br />37 <br />
The URL can be used to link to this page
Your browser does not support the video tag.