My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 126 Draft 01 2018-2020
ClerkCouncil
>
Council Records
>
Bills
>
2018-2020
>
BIL 126 Draft 01 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 10:00:45 AM
Creation date
12/2/2019 10:18:15 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2018-2020
Bill/Resolution
126
Draft
01
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
PWMTC
Action 1
Council: Bill 126 passes first reading; adopts PWMTC-20 - 1/8/20
Action 2
Council: Bill 126 passes second & final reading - 1/22/20
Status
Adopted
Date To Mayor or Adoption Date
1/30/2020
Reading Number
1
Reading Date
1/8/2020
Ayes
7-Chung, David, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes
0
Absent
2-Eoff, Kaneali'i-Kleinfelder,
Excused
0
Reading Number .
2
Reading Date .
1/22/2020
Ayes .
7- David, Eoff, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes .
0
Absent .
2-Chung, Kaneali'i-Kleinfelder
Excused .
0
Document Relationships
AGE COUNCIL 2020-01-08 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE COUNCIL 2020-01-22 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE PWMTC 2019/12/17 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Public Works & Mass Transit Committee (PWMTC)
COM 0646.000 2018-2020
(Related)
Path:
\Council Records\Communications\2018-2020
ORD 2020-010 2018-2020
(Related To)
Path:
\Council Records\Ordinances\2020
REP PWMTC 020 2019/12/17 2018-2020
(Related)
Path:
\Council Records\Reports\2018-2020\Public Works & Mass Transit Committee (PWMTC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. Those with a peak design rate of energy usage less than 3.4 Btu/h - ft' <br /> (10.7 W/m2) or 1.0 watt/ft'(10.7 W/mz) of floor area for space- <br /> conditioning purposes. <br /> 2. [ ] Unconditioned space that <br /> does not contain habitable space. <br /> 3. Unconditioned dwellings with enclosed habitable areas less than 1,100 <br /> square feet." <br /> 4. Dwellings with permitted, off-grid, self supplying photovoltaic with <br /> battery back up." <br /> (32) TABLE R402.1.2 of the International Energy Conservation Code is deleted in its <br /> entirety and replaced with the following: <br /> "TABLE R402.1.2 <br /> INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa <br /> WOOD CRAWL <br /> CLIMATE FENESTRATION SKYLIGHT GLAZED CEILING FRAME MASS FLOOR BASEMENT SLAB SPACE <br /> ZONE U-FACTOR° U-FACTOR FENESTRATION R-VALUE WALL WALL R-VALUE WALL R- WALL <br /> b SHGC b,c,g ° R-VALUE d R-VALUE R-VALUE VALUE R-VALUE <br /> j-f &DEPTH <br /> I NR 0.75 0.25 30 13 314 0 0 0 0 <br /> For SI: 1 foot=304.8 mm <br /> a. R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label or design <br /> thickness of the insolation,the installed R-value of the insulation shall not be less than the R-value specified in the table, <br /> b. The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration.Exception Sk- <br /> ylights may be <br /> excluded from glazed fenestration SHGC requirements in climate zones I through 3 where the SHGC for such skylights does not exceed <br /> 0.30. <br /> C. Exception:If fenestration have overhangs with projection factors,the maximum solar heat gain coefficient shall be as specified in Table <br /> R401.2.1. <br /> d. R4021.2 and R402.2 allow use of R407. <br /> e. The second R-value applies when more than half the insulation is on the interior of the mass wall <br /> f. Exception:R-value for mass walls are not required if:mass walls have a covering with reflectance of>0.64:mass walls have overhangs <br /> with a projection factor equal to or greater than 0.3.CMU or similar mass walls are 6 inches or greater in thickness. <br /> g. Exception:Jalousie windows are exempt from SHGC requirements." <br /> (33) Subsection 8402.1.2 of the International Energy Conservation Code is amended to <br /> read as follows: <br /> "R402.1.2 Insulation and fenestration criteria(Prescriptive). <br /> The building thermal envelope shall meet the requirements of Table R402.1.2, [bred <br /> an the climate zone speeffied in Ghaptef--3-.] <br /> Exception: Insulation values of above-grade walls and ceilings shall be permitted <br /> to comply with Section R407." <br /> 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.