My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 126 Draft 01 2018-2020
ClerkCouncil
>
Council Records
>
Bills
>
2018-2020
>
BIL 126 Draft 01 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 10:00:45 AM
Creation date
12/2/2019 10:18:15 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2018-2020
Bill/Resolution
126
Draft
01
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
PWMTC
Action 1
Council: Bill 126 passes first reading; adopts PWMTC-20 - 1/8/20
Action 2
Council: Bill 126 passes second & final reading - 1/22/20
Status
Adopted
Date To Mayor or Adoption Date
1/30/2020
Reading Number
1
Reading Date
1/8/2020
Ayes
7-Chung, David, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes
0
Absent
2-Eoff, Kaneali'i-Kleinfelder,
Excused
0
Reading Number .
2
Reading Date .
1/22/2020
Ayes .
7- David, Eoff, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes .
0
Absent .
2-Chung, Kaneali'i-Kleinfelder
Excused .
0
Document Relationships
AGE COUNCIL 2020-01-08 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE COUNCIL 2020-01-22 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE PWMTC 2019/12/17 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Public Works & Mass Transit Committee (PWMTC)
COM 0646.000 2018-2020
(Related)
Path:
\Council Records\Communications\2018-2020
ORD 2020-010 2018-2020
(Related To)
Path:
\Council Records\Ordinances\2020
REP PWMTC 020 2019/12/17 2018-2020
(Related)
Path:
\Council Records\Reports\2018-2020\Public Works & Mass Transit Committee (PWMTC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(34) Subsection R402.2 of the International Energy Conservation Code is amended to read <br /> as follows: <br /> "R402.2 Specific insulation requirements (Prescriptive). <br /> In addition to the requirements of Section R402.1, insulation shall meet the specific <br /> requirements of Sections 8402.2.1 through R402.2.13. <br /> Exception: Above-grade walls and ceilings shall be permitted to comply with <br /> Section R407." <br /> (35) Subsection R402.2.5 of the International Energy Conservation Code is amended to <br /> read as follows: <br /> "R402.2.5 Mass walls. Mass walls for the purposes of this chapter shall be <br /> considered above-grade walls of concrete block, concrete, insulated concrete form <br /> (ICF), masonry cavity,brick(other than brick veneer), earth (adobe, compressed <br /> earth block, rammed earth) and solid timber/logs, or any other walls having a heat <br /> capacity greater than or equal to 6 BtU/ft2 x'F (123 kJ/m2 x K). <br /> Exception: Insulation or R-value for mass walls, indicated in Table 8402.1.2, is <br /> not required when at least one of the following conditions is met: <br /> 1. Walls have a covering with a reflectance of> 0.64. <br /> 2. Walls have overhangs with a projection factor equal to or greater than 0.3. <br /> The projection factor is the horizontal distance from the surface of the wall <br /> to the farthest most point of the overhang divided by the vertical distance <br /> from the first floor level to the bottom most point of the overhang. <br /> 3. Concrete, CMU, and similar mass walls are 6 inches or greater in <br /> thickness." <br /> (36) Subsection R402.3.2 of the International Energy Conservation Code is amended to <br /> read as follows: <br /> "R402.3.2 Glazed fenestration SHGC. Fenestration shall have a maximum solar <br /> heat gain coefficient as specified in Table R402.1.2. An area-weighted average of <br /> fenestration products more than 50-percent glazed shall be permitted to satisfy the <br /> SHGC requirements. <br /> Exceptions• <br /> 1. Jalousie windows are exempt from SHGC requirements. <br /> 2. If fenestrations have overhangs with projection factors, the maximum <br /> solar heat gain coefficient shall be as specified in Table R401.2.1. <br /> Dynamic glazing shall be permitted to satisfy the SHGC requirements of Table <br /> R402.1.2 provided the ratio of the higher to lower labeled SHGC is greater than or <br /> 19 <br />