My WebLink
|
Help
|
About
|
Sign Out
Home
BIL 126 Draft 01 2018-2020
ClerkCouncil
>
Council Records
>
Bills
>
2018-2020
>
BIL 126 Draft 01 2018-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2020 10:00:45 AM
Creation date
12/2/2019 10:18:15 AM
Metadata
Fields
Template:
Bill/Resolution
Bill/Resolution - Type
BIL
Bill/Resolution - Council Term
2018-2020
Bill/Resolution
126
Draft
01
Introducer
Susan L. K. Lee Loy, Council Member
Referred To
PWMTC
Action 1
Council: Bill 126 passes first reading; adopts PWMTC-20 - 1/8/20
Action 2
Council: Bill 126 passes second & final reading - 1/22/20
Status
Adopted
Date To Mayor or Adoption Date
1/30/2020
Reading Number
1
Reading Date
1/8/2020
Ayes
7-Chung, David, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes
0
Absent
2-Eoff, Kaneali'i-Kleinfelder,
Excused
0
Reading Number .
2
Reading Date .
1/22/2020
Ayes .
7- David, Eoff, Kierkiewicz, Lee Loy, Poindexter, Richards, Villegas
Noes .
0
Absent .
2-Chung, Kaneali'i-Kleinfelder
Excused .
0
Document Relationships
AGE COUNCIL 2020-01-08 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE COUNCIL 2020-01-22 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Council
AGE PWMTC 2019/12/17 2018-2020
(Related To)
Path:
\Council Records\Agendas\2018-2020\Public Works & Mass Transit Committee (PWMTC)
COM 0646.000 2018-2020
(Related)
Path:
\Council Records\Communications\2018-2020
ORD 2020-010 2018-2020
(Related To)
Path:
\Council Records\Ordinances\2020
REP PWMTC 020 2019/12/17 2018-2020
(Related)
Path:
\Council Records\Reports\2018-2020\Public Works & Mass Transit Committee (PWMTC)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. The requirements of Sections C402.5, C403.2, C404, 0405.2, C405.3, C405.5, <br /> C405.6 and C407. The building energy cost shall be equal to or less than 85 <br /> percent of the standard reference design building. <br /> Exception: For buildings 2,500 square feet or less with 4 tons of cooling or less <br /> where it is determined by the code official that the building configuration is <br /> similar to that of a residential building,the requirements in Sections R401.2.1 <br /> Tropical Zone shall be permitted to be used." <br /> (8) Subsection C402.1.1 of the International Energy Conservation Code is amended to <br /> read as follows: <br /> "C402.1.1 Low-energy use buildings. The following low-energy use buildings, or <br /> portions thereof separated from the remainder of the building by building thermal <br /> envelope assemblies complying with this section, shall be exempt from the building <br /> thermal envelope provisions of Section C402. <br /> 1. Those with a peak design rate of energy usage less than 3.4 Btu/h•ft2 (10.7 <br /> W/m2) or 1.0 watt per square foot(10.7 W/M2) of floor area for space <br /> conditioning purposes. <br /> 2. [Those that do not eafftain eondit4oned-spaee] Unconditioned space that does <br /> not contain occupiable space and/or habitable space. <br /> 3. Greenhouses. <br /> 4. Open park pavilions where there is no enclosed space." <br /> (9) Table C402.1.3 from the International Energy Conservation Code is deleted in its <br /> entirety and replaced with the following: <br /> "TABLE C402.1.3 <br /> OPAQUE THERMAL ENVELOPE INSULATION COMPONENT <br /> MINIMUM REQUIREMENTS,RNALUE METHODa- CLIMATE ZONE I <br /> CLIMATE ZONE I <br /> All other Group R <br /> Roofs <br /> Insulation entirely R-10ci R-12.5 <br /> ci <br /> above roof deck <br /> Metal buildingsa,b R-30 or R-19 with cool roof R-30 or R-19 with cool roof <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.